Rose Electronics Orion X-series User Manual

Page 69

Advertising
background image

Orion X Installation and Operations Manual

61

Select between the following settings:
Field

Selection

Description

Function
(01-16)

Connect (P1=CON, P2=CPU)

Set bidirectional connection from console P1 to
CPU P2

Connect Video (P1=CON, P2= CPU)

Set video connection from console P1 to CPU
P2

Disconnect (P1=CON)

Disconnect console P1

Logout User

Logout current user

Set Real CPU (P1=VCPU, P2=RCPU)

Assign a virtual CPU to a real CPU

Set Virtual CON (P1=RCON, P2=VCON)

Assign a real console to a virtual console

Push (P1=CON)

The console’s KVM connection is forwarded to
console P1 and is changed to a video only
connection.

Push Video (P1=CON)

The video signal of the console’s current
connection (KVM or video only) is forwarded to
console P1. The console’s connection remains
unchanged (KVM or video only).

Get (P1=CON)

The console gets a KVM connection to the CPU
that is currently connected to console P1. The
connection of console P1 is changed into a
video only connection.

Get Video (P1=CON)

The console gets a video only connection to the
CPU that is currently connected to console P1.
The connection of console P1 remains
unchanged (KVM or video only).

P1

CON or CPU Device

Name of CON or CPU device

P2

CON or CPU Device

Name of CON or CPU device


Setting up Console Macros through the OSD
 Select via Configuration > CON Macros in the main menu that console for which a console macro has
to be created.

Figure 49. Setting up Console Macros through OSD

Advertising