Orion X Installation and Operations Manual

31

Access Control

The access control configuration is set in this menu. This menu can be accessed in the OSD and the Java

Tool.

The following settings can be modified.

Field

Selection

Description

Force User Login

Activated

Users must login with a user name and a password once to

enter OSD. Thereafter the user remains logged in until he

explicitly logs out or an auto logout is effected.

Note: When using the Force User Login function, console

favorites and console macros still remain active.

Deactivated

Function not active (default)

Enable User ACL

Activated

CPU access is restricted according to the permissions in the

ACL (Access Control List).

User login is required.

Switching by keyboard 'Hot Keys' requires a prior login.

Deactivated

Function not active (default)

Enable Console ACL Activated

CPU access is restricted according to the permissions in the

respective Console ACL (Access Control List). No login

required.

Deactivated

Function not active (default)

Enable new User

Activated

Newly created users automatically receive access to all CPUs.

Deactivated

Function not active (default)

Enable new CON

Activated

Newly created CON devices automatically receive access to

all CPUs.

Deactivated

Function not active (default)

Auto Disconnect

Activated

Upon opening the OSD, the console will be automatically

disconnected from the current CPU.

Deactivated

Function not active (default)

OSD Timeout

0-999 seconds

Period of inactivity after which OSD will be closed

automatically.

Select 0 seconds, for no timeout (default: 0 seconds)

Auto Logout

0-999 minutes

Period of inactivity of a logged-in user at a console after which

he will be automatically logged out at this console.

There might be a disconnect because of the logout, depending

on the defined rights in each CON and user ACL.

Select 0 minutes for an automatic user logout when leaving

OSD.

Using the setting -1 allows the user to be logged in

permanently, until a manual logout is executed.

The timer is not active as long as the OSD is open.

(default: 0 minutes)