Orion X Installation and Operations Manual

77

Addressing of Main and Sub Matrices

The Orion X can be cascaded to two levels. Commands (including opening the OSD) can be optionally sent
to the main or the sub matrix.

When command mode is activate, select <m> if the commands should be handled in the main matrix or <s>
to indicate the commands should be handled in the sub matrix.

OSD Access

4. Display the OSD of the main matrix:

<Left Shift>, <Left Shift>, <m> (optional), <o>

5. Display the OSD of the sub matrix:

<Left Shift>, <Left Shift>, <s>, <o>


Example: Switching to CPU port 23 of the sub matrix.

1. Switch to the CPU Port on the master matrix where the sub matrix is connected (e.g. 12):

<Left Shift>, <Left Shift>, <m> (optional), <1>, <2>, <Enter>

2. Then switch to CPU Port 23 on the sub matrix:

<Left Shift>, <Left Shift>, <s>, <2>, <3>, <Enter>


Note: The selected main matrix / sub matrix mode will remain activated until the other mode is manually
activated. This means that if <s> is currently selected for example, all subsequent commands will be sent
to the slave, as long as Command Mode remains active.