Facility, Tc63 at command set – Siemens TC63 User Manual

Page 129

Advertising
background image

TC63 AT Command Set

5.7 AT^SPWD

s

TC63_ATC_V00.490

Page 129 of 501

5/24/05

Confidential / Draft - Do not copy

Parameter Description

“CM“

Password used as Customer Mastercode for Customer SIM Lock.

Defining the "CM" password allows the application manufacturer to set a Cus-

tomer SIM Lock by activating a Network Personalization ("PN") with the

AT^SCSL

command. The "CM" password is mandatory for each operation with

AT^SCSL

.

<password length>

of "CM": 8 digits.

To delete the "CM" password use the following syntax:

AT^SPWD

=

<facil-

ity>

,

<old password>

. Please note that this action will delete all personali-

sation data programmed by the manufacturer with

AT^SCSL

(including the

operator list).

A description of all other passwords commonly supported by

AT+CPWD

and

AT^SPWD

can be found in Section

5.6

,

AT+CPWD

. The "CM" password cannot be edited with

AT+CPWD

.

Notes

• When changing the PIN2 (

<facility>

="P2") it is recommended to check the new state of PIN2 using the

AT+CPIN2

command.

• In the airplane mode the write command version for the network related

<facility>

(AO, OI, OX, AI, IR,

AB, AG and AC) is not supported. For remaining facilities the command is fully functional then.

Examples

EXAMPLE 1

To specify the "CM" password required as Customer Mastercode for the Customer SIM Lock:

EXAMPLE 2

To change the Customer Mastercode:

EXAMPLE 3

To delete the Customer Mastercode:

<facility>

(str)

AT^SPWD="CM"

Check if the Customer Mastercode was already set.

ERROR

No, it was not.

AT^SPWD="CM", ,"12345678"

Specify a new Customer Mastercode (where

<old

password>

is omitted and

<new pass-

word>

"12345678" = new Customer Mastercode)

OK

The Customer Mastercode has been set to

"12345678".

AT^SPWD="CM"

Checking again.

OK

Yes, it is active now.

AT^SPWD="CM","12345678","44444444"

(where "12345678" = old Customer Mastercode, and

"44444444" = new Customer Mastercode).

OK

The Customer Mastercode has been changed from

"12345678" to "44444444".

AT^SPWD="CM","44444444"

Delete the Customer Mastercode by omitting

<new

password>

and entering only the

<old pass-

word>

"44444444".

OK

The Customer Mastercode as well as all personali-

sation data programmed by the manufacturer with

AT^SCSL

were deleted.

Advertising