Tc63 at command set – Siemens TC63 User Manual

Page 426

Advertising
background image

TC63 AT Command Set

18.13 AT^SNFO

s

TC63_ATC_V00.490

Page 426 of 501

5/24/05

Confidential / Draft - Do not copy

Notes

<outCalibrate>

specifies the amount of volume of each

<outStep>

. The range of each

<outCali-

brate>

is up to 65535, but will be suppressed to 32767. A value above

<outCalibrate>

= 65535 will cause

an error.

• The range of

<sideTone>

is up to 65535, but will be suppressed to 32767. A value above

<sideTone>

=

65535 will cause an error.

• Any change to

<outStep>

takes effect in audio modes 2 to 6. That is, when you change

<outStep>

and

then select another mode with

AT^SNFS

, the same step will be applied. Nevertheless, the sound quality and

the amount of volume are not necessarily the same, since all remaining audio parameters can use different

values in either mode.

• Audio mode 1 is fixed to

<outStep>

=4. In this mode, any attempt to change

<outStep>

or other parameters

returns an error.

• The value of

<outStep>

is stored non-volatile when the ME is powered down with

AT^SMSO

or reset with

AT+CFUN

=x,1. Any other parameters changed with

AT^SNFO

need to be saved with

AT^SNFW

for use after

restart. See also

AT^SNFD

for details on restoring factory defaults.

• The values of

<outStep>

can also be changed with

AT^SNFV

and

AT+CLVL

.

• CAUTION! When you adjust audio parameters avoid exceeding the maximum allowed level. Bear in mind that

exposure to excessive levels of noise can cause physical damage to users!