1 me status indicated by status led patterns, Table 19.1, Modes of the led and indicated me functions – Siemens TC63 User Manual

Page 448: Section, Me status indicated by status led, Patterns, Me status indicated by, Status led patterns, Tc63 at command set

Advertising
background image

TC63 AT Command Set

19.6 AT^SSYNC

s

TC63_ATC_V00.490

Page 448 of 501

5/24/05

Confidential / Draft - Do not copy

19.6.1 ME status indicated by status LED patterns

The following table lists the possible patterns of status LED behavior, and describes the ME operating status indi-

cated by each pattern if

AT^SSYNC

parameter

<mode>

=1 and

<mode>

=2.

Table 19.1: Modes of the LED and indicated ME functions

LED behavior

ME operating status if

AT^SSYNC

=1

ME operating status if

AT^SSYNC

=2

Permanently off

ME is in one of the following modes:

POWER DOWN mode, AIRPLANE

mode, CHARGE ONLY mode, SLEEP

mode with no wake-up event is

progress.

ME is in one of the following modes:

POWER DOWN mode, AIRPLANE

mode, CHARGE ONLY mode.

600 ms on / 600ms off

Limited Network Service: No SIM card

inserted or no PIN entered, or network

search in progress, or ongoing user

authentication, or network login in

progress.

This applies no matter whether the ME

works at full functionality level

AT+CFUN

=1 or has entered a "tempo-

rary wake-up state" during one of the

CYCLIC SLEEP modes.

Same as for

AT^SSYNC

=1

75 ms on / 3 s off

IDLE mode: The mobile is registered to

the GSM network (monitoring control

channels and user interactions). No call

is in progress.

The same LED pattern applies when the

ME enters a "temporary wake-up state

during one of the CYCLIC SLEEP

modes (e.g. after characters have been

received on the serial interface).

Same as for

AT^SSYNC

=1

75 ms on / 75 ms off /

75 ms on / 3 s off

One or more GPRS contexts activated.

Same as for

AT^SSYNC

=1

500 ms on / 25 ms off

Packet switched data transfer in

progress.

Same as for

AT^SSYNC

=1

Permanently on

Depending on type of call:

Voice call: Connected to remote party.

Data call: Connected to remote party or

exchange of parameters while setting

up or disconnecting a call.

This applies no matter whether the ME

works at full functionality level

AT+CFUN

=1 or in one of the CYCLIC

SLEEP modes where it wakes up only

temporarily to make the call.

Same as for

AT^SSYNC

=1

n * 600 ms on / n * 600 ms

off

Not possible: With

AT^SSYNC

=1, LED

signalization is disabled in SLEEP

mode.

SLEEP mode is activated (

AT+CFUN

parameter

<fun>

≠ 1), but the ME is not

registered to the GSM network (e.g. SIM

not inserted or PIN not entered, and

therefore, either no network service or

only Limited Network Service is avail-

able.

Advertising