TC63 AT Command Set

7.23 AT+CR

s

TC63_ATC_V00.490

Page 172 of 501

5/24/05

Confidential / Draft - Do not copy

7.23

AT+CR Service reporting control

AT+CR

configures the TA whether or not to transmit an intermediate result code +CR:

<serv>

to TE when a call

is being set up.

Setting the value of

<mode>

to 1 may lead to connection failure, if the application (e.g. WinFax) waits for default

result code/URC.

Syntax

Intermediate Result Code

If enabled, an intermediate result code is transmitted during connect negotiation when the TA has determined

the speed and quality of service to be used, before any error control or data compression reports are transmitted,

and before any final result code (e.g. CONNECT) appears.

+CR:

<serv>

Parameter Description

0

(&F)

Disable

1

Enable

“REL ASYNC“

Asynchronous non-transparent

“GPRS“

GPRS

Test Command

AT+CR=?

Response(s)

+CR:

(list of supported

<mode>

s)

OK

ERROR

Read Command

AT+CR?

Response(s)

+CR:

<mode>

OK

ERROR

Write Command

AT+CR=

<mode>

Response(s)

OK

ERROR

Reference(s)

PIN

ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge

4

Last

GSM 07.07

%

%

%

%

%

%

%

!

%

!

<mode>

(num)(&W)(&V)

<serv>

(str)