Chapter 7. PARAMETER SETUP

7-27

Setup data settings “

S

E

t

No.

Item Code

Item

Factory

User

Setting

Setting

Setting

1

C

0

1

0

2

C

0

2

0

3

C

0

3

0

4

C

0

4

Not fixed

5

C

0

5

Not fixed

6

C

0

6

Not fixed

7

C

0

7

0.0

8

C

0

8

0

9

C

0

q

0%FS

10

C

1

0

100%FS

0: Reverse action (heat)

1: Direct action (cool)

[Note]

On heat/cool models, “– – – –” is displayed and setting
is not possible.
On other models, external switch input can invert
direct/reverse action on the setting of

C

0

1

.

0:

°

C

1:

°

F

[Note]

When the input 1 range type is linear, “– – – –” is

displayed and setting is not possible.

0 to 73

0 to 20: Thermocouple

32 to 40, 48 to 56: Resistance temperature detector

64 to 73: Linear (dc current, dc voltage)

[Note]

Refer to the input 1 range table. Operation according

to a setting not listed in this table is not fixed.

0 to 3

[Note]

When the input 1 range type is non-linear, “– – – –” is

displayed and setting is not possible.

When the input 1 range type is changed from non-

linear to linear, the original non-linear range values

remain.

-1999 to 9999U

[Note]

When the input 1 range type is non-linear, “– – – –” is

displayed and setting is not possible.

When the input 1 range type is changed from non-

linear to linear, the original non-linear range values

remain.

The relationship between the analog inputs and

readout values can be inverted by inverting the upper

and lower limit values.

0.0 to 10.0% (ratio to input range)

[Note]

0.0 disables square root extraction.

When the input 1 range type is non-linear, “– – – –” is

displayed and setting is not possible.

0: Disabled

1: Enabled

[Note]

Table data setting (

a

,

b

) is used for the linearization

table.

-1999 to upper limit U

[Note]

Changing the input 1 range has no effect on the range.
However, note that a general reset sets the range to
the 0%FS value of the input 1 range.

Lower limit to 9999U

[Note]

Changing the input 1 range has no effect on the range.

However, note that a general reset sets the range to

the 0%FS value of the input 1 range.

Control action (CH1)

Input 1 temperature

unit

Input 1 range type

Input 1 range

decimal point

position

Input 1 range lower

limit (0%)

Input 1 range upper

limit (100%)

Input 1 root extrac-

tion dropout

Input 1 linearization

table approximation

SP1 lower limit

SP1 upper limit