Programming map – Sonic Alert Digital Program Controller DCP301 User Manual

Page 131

Advertising
background image

Chapter 8. PROGRAM SETUP

8-4

Programming map

As shown in the figure below, the programming map is arranged in a matrix with the
segment Nos. aligned along the horizontal axis and program setup items arranged along
the vertical axis.

The area surrounded by thick black lines indicates the items that can be designated by
segment No. and program setup item in the program setup state.

,

:

Moves to the left or right (i.e. moves segments)

,

:

Moves up or down (i.e. moves program items).

The programming map below shows an example where segments No.1 to No.10 have
been set up.

Shaded items

cannot be moved.

Segment No.

Program (1) No.1 setting

1

2

. . . .

10

11

12 to 30

Remarks

Items

(2) No.2 setting

Pattern

(1) SP1

1 0 0

1 0 0 0

1 0 0

- - - -

*1

(2) Time

0 . 3 0

3 . 0 0

1 0 . 0 0

- - - -

Event 1

(1) Operating point (ON time)

1 1 0 0

- - - -

- - - -

*2

(2) (OFF time)

Event 2

(1) Operating point (ON time)

- - - -

3 0

- - - -

(2) (OFF time)

Event 3

(1) Operating point (ON time)

0 . 0 0

0 . 0 0

0 . 0 0

(2) (OFF time)

0 . 0 1

0 . 0 1

0 . 0 1

(1) ON time

- - - -

0 . 0 0

- - - -

*3

(2) OFF time

- - - -

1 . 0 0

- - - -

(1) ON time

- - - -

1 . 0 0

- - - -

(2) OFF time

- - - -

2 . 0 0

- - - -

(1) ON time

- - - -

2 . 0 0

- - - -

(2) OFF time

- - - -

3 . 0 0

- - - -

(1) ON time

- - - -

- - - -

- - - -

(2) OFF time

- - - -

- - - -

- - - -

(1) ON time

- - - -

- - - -

0 . 0 0

(2) OFF time

- - - -

- - - -

- - - -

PID set No. (CH1)

1

2

8

*4

G.Soak (CH1)

- - - -

- - - -

- - - -

G.Soak time-out

- - - -

- - - -

- - - -

PV start

1

1

1

*5

Cycle

0

0

0

Pattern link

0

0

0

Time
event 1

Time
event 2

Time
event 3

Time
event 4

Time
event 5

*1 The No.10 segment is the final segment. A non-set segment is shown in the No.11

segment.

*2 As PV type event is selected as the PV type for events 1 and 2, only the No.1 setting

can be set up. As time event is selected as the event type for event 3, the No.1 and
No.2 settings can be set up.

*3 As all time events are selected as the event type in the time event, the No.1 and No.2

settings can be set up.

*4 This can be set as controller functions are selected and PID or ON-OFF control is

carried out.

*5 As these are setting items for each program, the display and setting are common for

all segments.