Sonic Alert Digital Program Controller DCP301 User Manual

Page 116

Advertising
background image

Chapter 7. PARAMETER SETUP

7-31

No.

Item Code

Item

Factory

User

Setting

Setting

Setting

67

C

6

7

68

C

6

8

0

69

C

6

q

0

70

C

7

0

0

71

C

7

1

0

72

C

7

2

0

73

C

7

3

0

74

C

7

4

0

75

C

7

5

Not fixed

76

C

7

6

Not fixed

77

C

7

7

78

C

7

8

15

79

C

7

q

15

80

C

8

0

81

C

8

1

0

Alarm display

Programming item:

Events 1 to 3

Programming item:

Time events 1 to 5

Programming item:

PID set, G.Soak
Programming item:
PV start, cycle,
pattern link

Cold junction

compensation

Input operation at

input 1 disconnec-

tion

Voltage time-

proportional output

system

Output 1 selection

Output 2 selection

Unused

Voltage output 1

adjustment

Voltage output 2

adjustment

Unused

Input 1 burnout cur-

rent (expansion set-

ting 1)

0: Display ON

1: Display OFF
[Note]

Even when set to 1, alarm-related events do not

operate.

0: Display ON

1: Display OFF

[Note]

Even if each of the items are set to 1, the function

operates even if data is set to the program.

On models not supporting time events, time event

items are not displayed in program settings regardless

of the number of

C

6

q

settings.

0: Compensated internally

1: Compensated externally

[Note]

When the input 1 range type is other than a thermo-

couple, “– – – –” is displayed and setting is not

possible.

0: Upscale

1: Downscale

[Note]

This setting is valid when the input 1 range type is

thermocouple, resistance temperature detector or

linear (mV series).

0: Input ON again enabled within time-proportional cycle

1: Input ON again disabled within time-proportional cycle
[Note]

When both of outputs 1 and 2 are not voltage time-

proportional outputs, “– – – –” is displayed and setting

is not possible.

0: Current output

1: Voltage output
[Note]

When each of the outputs are relay output, position-

proportional output, auxiliary output or output is not

mounted, “– – – –” is displayed and setting is not

possible.

Factory setting is 1 if outputs are voltage output

according to output type. Otherwise, the setting is 0.

[Note]

“– – – –” is displayed and setting is not possible.

2 to 22mA
[Note]

When each of the outputs are other than voltage output,

“– – – –” is displayed and setting is not possible.

Normally, use the factory setting.

[Note]

“– – – –” is displayed and setting is not possible.

0: Burnout current ON

1: Burnout current OFF

[Note]

Normally set to 0.

Set to 1 when infra-red thermocouple RT50 is connected

to input 1.

Advertising