Constant-value operation data settings “ c n s t – Sonic Alert Digital Program Controller DCP301 User Manual

Page 127

Advertising
background image

Chapter 7. PARAMETER SETUP

7-42

Constant-value operation data settings “

C

N

S

t

No.

Item Code

Item

Factory

User

Setting

Setting

Setting

1

M

.O

D

E

0

2

S

P

0

3

S

P

2

0

4

E

V

1

9999

5

E

V

2

9999

6

E

V

3

9999

7

8

9

10

11

P

.

100.0

12

I

.

0

13

D

.

0

14

O

L

.

0.0

15

O

H

.

100.0

16

R

E

.

50.0

17

B

R

.

0

18

D

P

.

100.0

19

D

I

.

120

20

D

D

.

0

21

P

.-C

100.0

22

I

.-C

0

23

D

.-C

0

24

O

L

.-C

0.0

25

O

H

.-C

100.0

26

R

E

.-C

50.0

27

28

29

30

0: Program operation

1: Constant-value operation
[Note]

This setting can be changed only in the READY mode.

This setting can be set in the SP1 lower to upper limit

range in setup data settings

C

0

q

and

C

1

0

.

[Note]

“– – – –” is displayed and setting is not possible.

-1999 to 9999U

(event type is deviation or SP)

0 to 9999U

(event type is absolute value deviation)

-10.0 to 110.0%

(event type is MV or MFB)

[Note]

When the event configuration data type setting is

50

for each event, “– – – –” is displayed and setting is not

possible.

[Note]

“– – – –” is displayed and setting is not possible.

P

: 0.0 to 999.9% (0D, 6D output models)

0.0 enables ON-OFF control.

0.1 to 999.9% (models other than 0D and 6D

models)

I

: 0 to 3600s

0 disables integral action.

D

: 0 to 1200s

0 disables derivative action.

O

L

: -10.0 to MV upper limit %

O

H

: MV lower limit to 110.0%

R

E

: 0.0 to 100.0%

B

R

: 0 to 30

0 disables the brake function.

D

P

: 0.1 to 999.9%

D

I

: 1 to 3600s

D

D

: 0 to 1200

0 disables derivative action.

[Note]

• On 0D and 6D output models, when

P

setting is 0.0,

ON-OFF control is enabled. “– – – –” is displayed for

items

I

,

D

,

O

L

,

O

H

,

R

E

,

D

P

,

D

I

and

D

D

, and

setting is not possible.

• When variable parameter

M

.-C

setting is 2 (estimated

position control only) on 2G output models, “– – – –” is

displayed for items

OL

and

OH

, and setting is not

possible.

• When

I

setting is not 0, “– – – –” is displayed for

R

E

and setting is not possible.

• When variable parameter

S

T

setting is 0 (smart-tuning

disabled), “– – – –” is displayed for

B

R

and setting is

not possible.

• When variable parameter

2

P

I

D

setting is 0 (2

degrees of freedom PID disabled), the items for

D

P

,

D

I

,

D

D

are not displayed.

For details, see the Note for PID parameters.

[Note]

“– – – –” is displayed and setting is not possible.

Operation mode

SP1

Unused

Event 1 setting

value

Event 2 setting

value

Event 3 setting

value

Unused

Unused

Unused

Unused

Proportional band

(CH1)

Reset time (CH1)

Rate time (CH1)

MV lower limit (CH1)

MV upper limit (CH1)

Manual reset (CH1)

Brake (CH1)

Disturbance inhibit

proportional band

(CH1)

Disturbance inhibit

reset time (CH1)

Disturbance inhibit

rate time (CH1)

Proportional band

(for cool control)

Reset time (CH1)

(for cool control)

Rate time (CH1) (for

cool control)

MV lower limit (CH1)

(for cool control)

MV upper limit (CH1)

(for cool control)

Manual reset (CH1)

(for cool control)

Unused

Unused

Unused

Unused

Advertising