Chapter 10. SPECIFICATIONS

10-1

19

30 per program

RAMP-X system: Set by set points (SP) and time.

0 to 99h 59min, or 0 to 99min 59s (time unit selectable)

±

0.01% (0.1s delay when segment time setting=0)

Set operating point.

Set ON and OFF times.

Set 0 to 8 (Set 0 for continuation of previous segment) (Set 0 to 4 on heat/cool models.)

Sets G.Soak width 0 to 1000U.

Sets program ON/OFF.

Sets program count 0 to 9999.

Sets program No.0 to 19 (0: no link)

Sets 8 alphanumerics for each program (not displayed on controller)

Thermocouple, resistance temperature detector, dc voltage, dc current multi-range

(See pages 2-8 and 2-9.)

±

0.1%FS

±

1U (varies according to standard conditions, display value conversion and

range)

• At -100

°

C max. of K and T thermocouples:

±

1

°

C1U

• At 260

°

C max. of B thermocouple:

±

4%FS

±

1U

At 260 to 800

°

C:

±

0.4%FS

±

1U

At 800 to 1800

°

C:

±

0.2%FS

±

1U

• At 100

°

C max. of R and S thermocouples:

±

0.2%FS

±

1U

At 100 to 1600

°

C:

±

0.15%FS

±

1U

• At 300

°

C max. of PR40-20 thermocouple:

±

2.5%FS

±

1U

At 300 to 800

°

C:

±

1.5%FS

±

1U

At 800 to 1900

°

C:

±

0.5%FS

±

1U

• Golden iron chromel thermocouple:

±

1.5K

±

1U

• 2-digit range past decimal point by resistance thermometer detector input:

±

0.15%

±

1U

• At 0 to 10mV range:

±

0.15%FS

±

1U

• At -100

°

C max. of DIN U thermocouple:

±

2

°

C

±

1U

At -100 to 0

°

C:

±

1

°

C

±

1U

• At -100

°

C max. of DIN L thermocouple:

±

1.5

°

C

±

1U

0.1s

Thermocouple, dc voltage input:

±

1.3

µ

A max. (at peak value, under standard conditions)

At 1V min. range: 3

µ

A max.

dc current input:

50

±

10% (under operating conditions)

RTD input: 1.04mA

±

0.02mA, current flow from terminal A (under operating conditions)

Changes in readout value at wiring resistance of 250

at both

ends are as follows by input conversion:

• 0 to 10mV, -10 to 10mV: Within 35

µ

V

• 0 to 100mV:

Within 60

µ

V

• Other:

Within 750

µ

V

RTD input:

±

0.01%FS max. in wiring resistance range 0 to 10

Range of F01, F33, F38, P01, P33 and P38:

±

0.02%FS/

max.

Allowable wiring resistance is 85

max. (including Zener barrier

resistance. When Zener barrier is used, this applies only to

ranges other than F01, F33, F38, P01, P33 and P38. Note that

site adjustment is required.)

Thermocouple disconnection detection allowable parallel resistance: 1M

min.

Thermocouple, dc voltage input: -5 to +15Vdc

dc current input:

50mAdc, 2.5Vdc

Upscale and downscale can be internally selected. (dc current input and dc voltage

input of 1V or more are only downscaled.)

Item

Specification

Program

Number of programs

Number of segments

Segment setting system

Segment time

Basic time accuracy

Events (3)

Time events (5)

PID set No.

G.Soak

PV start

Cycle

Pattern link

Tag

Input

Input type

Input readout accuracy

Input sampling cycle

Input bias current

Input impedance

Measuring current

Influence of wiring resis-

tance

Allowable parallel resistance

Max. allowable input

Burnout