Chapter 11. CALIBRATION

Figure 11-1. Calibration Flowchart (1/2)

11-4

Notes:

*

; 1. This display shows the digits shown in the previous indication.

2. If wrong key operation is made when moving from one to another item, the display is returned

to the initial status of calibration mode. But, the mode is still in the calibration mode.

While pressing , press and simultaneously.

&

Function test

Key ON/OFF

Key ON/OFF

PROG

SEG

0 0

0 1

Key test

Display test

PROG

SEG

ON/OFF of display

ON/OFF of display

DI test

DI ON/OFF

Control output test
Relay Voltage pulse

Do output test

PV input
calibration item

1.0.1.1.

*

A d J S

Gain No. selection

0 0 0 0 0

*

A d J S

Zero input count

After stabilized,
press .

Span input count

After stabilized,
press .

Input of Control
output ON/OFF

Input of DO
ON/OFF

0.0.0.0.

*

A d J S

PROG

SEG

0 0

0 0

PROG

SEG

0 0

0 3

PROG

SEG

0 0

0 4

PROG

SEG

0 0

0 5

PROG

SEG

0 1

0 0

PROG

SEG

0 1

0 1

PROG

SEG

0 1

0 2

PROG

SEG

0 0

0 3

Current input
count No.

Current count No.
stored

Current input
count No.

Current count No.
stored

ENTER

ENT

FUNC

&

ENTER

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

SETUP

ENTER