5-6

1-5V Input

Select 1-5V.

Set the channel range.

Set the left span value.

Set the right span value.

Set the left scale value.

Set the right scale value.

Turn On or Off the low-cut function.

The new setting takes effect.

First channel

(Select the right scale value.)

Last channel

ESC/?

Set=Range

CH=01-01

Mode=1-5V

Span_L= 1,000

Span_R= 5,000

Scale_L= 0.00

Scale_R= 200.00

Low-cut=Off

01-01 Channel
Setting complete

Description

• Span Left and Span Right

Selectable span left range: 0.8 to 1.2 V

Selectable span right range: 4.8 to 5.2 V

• Scale Left and Scale Right

Selectable range (mantissa): –20000 to 30000

Decimal position: XXXXX, XXXX.X, XXX.XX, XX.XXX, X.XXXX

The decimal position is the position specified by scale left.

Make sure that scale left is less than scale right.

• Low-cut

On: Cuts values below 0% of the recording span (set to 0% (scale left value)).

Off: Does not apply the low-cut function.

Note

The displayable/printable range of scale values is –19999 to 30000 excluding the decimal.

If the leftmost value of the scale is set to –20000 (excluding the decimal), the value when the

low-cut function is applied is displayed as “–Over.”