• Scale

Prints the leftmost and rightmost values of the recording span and the channel

number or tag for channels that have scale printout specified. The scale is printed for

one channel at each periodic printout. The channel whose scale is printed changes in

ascending order. The scale of channels that are being zone recorded is printed within

the recording range of the zone.

• Recording color

Prints the recording colors of channels that have scale printout and recording color

printout specified.

• Chart speed

Prints the chart speed.

Report Mode

Time tick cancel mark

Offset compensation mark/event

Sum value

Min./Max./Ave.

Unit

Range change
occurrence mark

Measured value

Channel No. or tag

Report start date/time

Report end date/time

Channel data

Computation channel

Scale

Recording color

Chart speed

Time tick

Mar.31.2004 15:00!
-Apr.01.2004 15:00*TPR
TAG-001*1.000V
2 -1.000V
3 -2.105500E+03UNIT03
4 2.000V
TAG-00A 1UNIT0A
C *1.00
D -10.00UNIT0D
150.00UNIT0D
100.00UNIT0D
E 1.0000%
J -1.00UNIT0J
0.000 2.000
TAG-001

V

RED
50mm/h_

• Report start date/time and report end date/time

The start date/time and end date time of the report (statistical calculation) (periodic

printout interval).

• Time tick and time tick cancel mark

These are the same as with the instantaneous mode.

• Offset compensation mark

This is the same as with the instantaneous mode.

• Event

Prints the events that occurred in the interval.

T: Time change

P: Power failure or power OFF/ON

R: Data reset

• Channel data

Prints the channel numbers (1 to 6 or A to J) or tags, report data, and unit.

An asterisk (*) is printed for channels whose range type was changed in the interval.

• Scale, recording color, and chart speed

These are the same as with the instantaneous mode.