Setup Operations for Changing/Adding Functions (Basic Setting Mode)

7

7.17 Initializing the Settings

This section explains the details of initializing the recorder settings to their factory

default.

Be careful, because all settings except the date/time setting in the recorder will be

initialized.

Basic Setting mode cannot be entered when recording is in progress or when

computation is in progress on models with the computation function (/M1 option).

Procedure

1.

Hold down the

MENU

key for 3 seconds to enter Setting mode.

2.

Hold down the

and

keys simultaneously for 3 seconds to enter Basic

Setting mode.

3.

Press the

key or SHIFT +

key to select Initialize and then press the

key.

4.

Press the

key to select the settings to be initialized and then press the

key.

Set:

Initializes the settings in Setting mode.

Setup+Set: Initializes the settings in Basic Setting mode and Setting mode.

5.

To execute the initialization, press the

key to select Yes and then press the

key.

The settings are initialized, and the recorder returns to Operation mode.

To cancel the initialization, press the ESC key The screen returns to the

Basic=Initialize

screen.

If you press the

key to select No and press then the

key, nothing

happens.

Select the range to be initialized.

Select Yes and press

to execute

initialization and return to Operation
mode.

ESC/?

Basic=Initialize

Mode=Setup+Set

Are you sure?=No

Explanation

Items That Are Not Initialized

The following items are not initialized.

• Adjustment value of the pen position and the adjustment value of the printer carriage

position (Basic Setting mode)

• Date/Time (Setting mode)