Introduction

Section 6-1

C200HX/HG/HE PLCs

Note

1.

Words in the Internal Relay Area 1 (IR 000 to IR 235) and Special Relay
Area 1 (SR 236 to SR 255) are continuous in memory, and any range of
words within these areas can be transferred in a single operation. The
same is true for Special Relay Area 2 (SR 256 to SR 299) and Internal Re-
lay Area 2 (IR 300 to IR 511). You cannot, however, transfer data in a range
that crosses the boundary between Special Relay Area 1 (SR 236 to SR
255) and Special Relay Area 2 (SR 256 to SR 299).
SR 253 to SR 255 cannot be written at the source node, even if they are
specified by the RECV instruction’s beginning receive word at the source
node.

2.

For details on extended DM Area and the number of banks, refer to the op-
eration manual for the PLC model that is being used.

CVM1 and CV-series PLCs

Note

1.

Writing is not possible to words G000 through G007 in the CPU Bus Link
Area.

2.

Writing is not possible to words A256 through A511 in the Auxiliary Area.

3.

Expansion DM can be used by mounting an Expansion DM Unit to a
CV1000/2000 or CVM1-CPU11/21 PLC. A maximum of eight banks can be
used, depending on the type of Expansion DM. For details, refer to the
CVM1 and CV-series PLC operation manuals.

CQM1H-series PLCs

Area

Range

Internal Relay Area 1

IR 000 to IR 235 (See note 1.)

Special Relay Area 1

SR 236 to SR 255 (See note 1.)

Special Relay Area 2

SR 256 to SR 299 (See note 1.)

Internal Relay Area 2

IR 300 to IR 511 (See note 1.)

Link Relay

LR 00 to LR 63

Holding Relay

HR 00 to HR 99

Timer/Counter

T/C 000 to T/C 511

Auxiliary Relay

AR 00 to AR 27

DM Area

DM 0000 to DM 6655

Extended DM Area

EM 0000 to EM 6143 (See note 2.)

Area

Range

CV500, CVM1-CPU01

CV1000/2000,

CVM1-CPU11/21

CIO Area

CIO 0000 to CIO 2555

CPU Bus Link Area

G000 to G255 (See note 1.)

Auxiliary Area

A000 to A511 (See note 2.)

Timer Area

T000 to T511

T000 T1023

Counter Area

C000 to C511

C000 to C1023

DM Area

DM0000 to DM8191

DM0000 to DM24575

Expansion DM Area

---

EM00000 to EM32765 (See
note 3.)

Area

Range

IR/SR Area

IR 000 to SR 255 (See note 1.)

LR Area

LR 00 to LR 63

HR Area

HR 00 to HR 99

Timer/Counter Area

TIM/CNT 000 to TIM/CNT 511

AR Area

AR 00 to AR 27