151

TANDBERG 3000

MXP

&

6000

MXP

REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Command Information

D 13887.08
MAY 2008

Required parameters are identified by an

(r)

appended to the parameter name. The

(r)

appears in this table for your information only and shall not be included when writing the commands – see the column Example for an illustration of this. Empty lines in the examples provided may have been removed to save space in the tables.

Command

Description

Parameters

Result parameters

when OK

Result parameters

when error

Example

DefaultValuesSet

Command used to reset
configurations to factory
default values.

Level: <1..3>
Configurations are divided into
three different storage levels.
The level parameter denotes that
configurations on this level and all
levels below (lower value) are to be
reset.
The complete list of Storage Levels
can be found in

Configuration

Storage Levels

.

None

As above

xcommand defaultvaluesset level:2

*r Result (status=OK):

*r/end

OK