REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Configuration-type Commands – xconfiguration / configuration.xml

D 13887.08
MAY 2008

Camera [1..13]

Gamma

Mode: <Auto/Manual>
Auto is the default and the recommended setting. However, in severe light conditions, you may switch mode to
manual and specify explicitly which gamma table to use by setting the level. Applies to TANDBERG Precision HD
cameras only.

Example:

xConfiguration camera 1 gamma mode: auto

Camera [1..13]

Gamma

Level: <0..7>
Selects which gamma correction table to use. This setting may be useful in difficult lighting conditions, where
changes to the the brightness setting does not provide satisfactory results. Applies to TANDBERG Precision HD
cameras only.

Example:

xConfiguration camera 1 gamma level: 5

See the comment about camera
ranges on the previous page.

Camera [1..13]

IR: <Off/On>
Default is On for camera 1 and 8. Default is Off for cameras 2 - 7 and 9 - 13.
Enables or disables the IR receiver of the camera. Only supported on WAVE, WAVE II and Precision HD cameras

Example:

xConfiguration camera 1 ir: on

CameraDVI

Mode: <On/Off/Auto>
Lets you control cameras connected to the PC Input.

The Auto mode, which is the default, will detect if you connect two PrecisionHD cameras, where one is first and the other is last in the chain. If that’s the case, control of the 2nd
PrecisionHD camera is automatic when the PC Input is selected.

If you have any other type of camera with a VGA/DVI/HDMI output, you must put it last in the chain, and manually turn this configuration On. When you select the PC Input, you
will gain control of the last camera. This configuration may be useful when using the VGA output on a Sony BRC-H700 camera.

Important

: If you set this configuration to on with a single PrecisionHD camera connected, the system will assume that it is connected to the PC Input and avoid

configuring the THSI interface. This may or may not be what you intended.

When set to Off the system assumes all cameras are connected to the normal video inputs, and/or THSI. May be useful if you connect a 2nd PrecisionHD camera to the codec
via an HDMI to s-video/composite converter.

Important

: Changing any of these options may require a hard boot of connected PrecisionHD cameras and a soft boot of the codec. If you experience problems, like

no video or get the message “unsupported video format”, make sure that all connected PrecisionHD cameras are turned off, reboot the codec, and turn cameras

back on.

Example:

xConfiguration cameradvi mode: auto

CameraSleep

Mode: <On/Off>
If turned On, the main camera will go into sleep position (maximum right panning) when screensaver is activated.
In addition, video source 1 (maincam) will be selected (if not allready active).

Example:

xconfiguration camerasleep mode: on

Camera [1..13]

cont...

— CameraSleep