Externalnetwork – TANDBERG 6000MXP User Manual

Page 193

Advertising
background image

193

TANDBERG 3000

MXP

&

6000

MXP

REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Status Information – xstatus /xstatus.xml

D 13887.08
MAY 2008

Status information followed by a

*

will not be shown unless Detailed Level has been set to 2

see

XACLI – Special commands – xpreferences

ExternalNetwork

(ready =

True / False

):

If ready =

False

the following will be included:

<Nothing>

If ready =

True

the following will be included:

ExternalClockRate:

Channel

(status =

Idle / Calling / Answering / Proceeding / Connect / Disconnecting / Disconnected

)

If status =

Idle

the following will be included:

<Nothing>

If status =

Calling / Answering / Proceeding / Connect

the following will be included:

CallingNumber:

ConnectionTime:

If status =

Disconnecting / Disconnected

the following will be included:

CallingNumber:

CauseLocation:

ChannelCause:

ConnectionTime:

ExternalNetwork

Advertising
This manual is related to the following products: