Call, Cont – TANDBERG 6000MXP User Manual

Page 174

Advertising
background image

174

TANDBERG 3000

MXP

&

6000

MXP

REFERENCE GUIDE FOR SYSTEM INTEGRATORS

Status Information – xstatus /xstatus.xml

D 13887.08
MAY 2008

Status information followed by a

*

will not be shown unless Detailed Level has been set to 2

see

XACLI – Special commands – xpreferences

Example (see previous page for the status information applicable):
*s Call 1 (status=Synced, type=Vtlph, protocol=H320, direction=Outgoing, logTag=3):

CallRate: 384

Bonding: On

RemoteNumber 1: “8776”

RemoteNumber 2: “”

RemoteSubAddress: “”

Mute: Off

Microphone: On

Duration: 32

MuteOutgoing: Off

Channels 1 (type=Incoming):

Rate: 384

Restrict: Off

Encryption (status=On):

Type: AES-128

CheckCode: “BA8C78DAD933C3DD”

Audio (status=Active):

Protocol: AAC-LD

Rate: 64

Video 1 (status=Active):

Protocol: H264

Resolution: 2.5SIF

Rate: 317

Video 2 (status=Inactive): /

Data (status=Inactive): /

Channels 2 (type=Outgoing):

Rate: 384

Restrict: Off

Encryption (status=On):

Type: AES-128

CheckCode: “BA8C78DAD933C3DD”

Audio (status=Active):

Protocol: AAC-LD

Rate: 64

Video 1 (status=Active):

Protocol: H264

Resolution: 4CIF

Rate: 317

Video 2 (status=Inactive): /

Data (status=Inactive): /

*s/end