Example showing Serial Port configurations of a TANDBERG
6000

MXP

codec, using the standard

XACLI

formatting for

configurations:
xconfiguration serialport
*c xConfiguration SerialPort 1 BaudRate:

57600
*c xConfiguration SerialPort 1 Parity: None
*c xConfiguration SerialPort 1 DataBits: 8
*c xConfiguration SerialPort 1 StopBits: 1
*c xConfiguration SerialPort 1 Mode: Control
*c xConfiguration SerialPort 2 BaudRate: 9600
*c xConfiguration SerialPort 2 Parity: None
*c xConfiguration SerialPort 2 DataBits: 8
*c xConfiguration SerialPort 2 StopBits: 1
*c xConfiguration SerialPort 2 Mode: Auto
OK

Example: To address the BaudRate element of serial port 2:

XPath

Each level is separated with a slash (‘/’). Item numbers are
added in brackets after the element name:
SerialPort[2]/BaudRate
Example
xconfiguration serialport[2]/baudrate
*c xConfiguration SerialPort 2 BaudRate: 9600
OK

TANDBERG SimplePath

Both levels and item numbers are separated with whitespac-
es:
SerialPort 2 BaudRate
Example
xconfiguration serialport 2 baudrate
*c xConfiguration SerialPort 2 BaudRate: 9600
OK

About the TANDBERG API

The TANDBERG

MXP

also supports the RS 232/Telnet Da-

taport Interface that was supported on the Classic systems.
You may use any mixture of Classic Dataport commands and
XACLI commands on the same RS232/Telnet session. A
multitude of the commands overlaps, but XACLI offers more
flexibillity and gives access to the latest features supported
by the system.

We recommend the use of XACLI commands

whenever

you write new control system modules and whenever you add
new features into existing control modules, but there is no
need to to rewrite already existing control modules based on
Classic commands.
The XACLI API is described in detail in this section of the User
Guide. The Classic Dataport Interface is described in the
TANDBERG 770-8000MXP API (Dataport User Guide), which is
available separately.

NOTE!

New features on the TANDBERG

MXP

will be sup-

ported on XACLI only.

EXAMPLE:

To configure the baudrate of serial port 1 to

9600:

Classic Dataport:

sport data1 9600

XACLI:

xconfiguration serialport 1 baudrate:

9600