HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 116

Advertising
background image

NOTE:

To utilize, for example, the volume replication function within the storage system when the RAID
Manager instance for managing the primary volumes and the RAID Manager instance for managing
the secondary volumes are on the same server, specify the instance numbers as indicated below:
- Specify both

HORCMINST

and

HORCMINST_AUX

.

For instance numbers to specify for

HORCMINST

and

HORCMINST_AUX

, see

Table 24

.

- The values for

HORCMINST

and

HORCMINST_AUX

are reversed when specifying settings for either

file servers and database servers, or for backup servers.
To utilize, for example, the volume replication function between storage systems when the RAID
Manager instance for managing the primary volumes and the RAID Manager instance for managing
the secondary volumes are on separate servers, specify the instance numbers as indicated below:
- Specify only

HORCMINST

(not

HORCMINST_AUX

).

For instance numbers to specify for

HORCMINST

, see

Table 24

.

- The RAID Manager instances specified in

HORCMINST

must be started on each server.

If a RAID Manager instance which is not located on the server is specified in

HORCMINST_AUX

, an

error message indicating failure to start the RAID Manager instance is output to the application log.
If the instance is not associated with the subject of processing, processing of the Application Agent
command will continue despite this error message. Also, the result of the command will not be affected.
It is recommended that you start the RAID Manager instances specified in

HORCMINST

and

HORCMINST_AUX

before executing a Application Agent command.

When specifying multiple instance numbers in

HORCMINST

and

HORCMINST_AUX

, write each

instance number on a separate line, as shown below:

HORCMINST=0

HORCMINST_AUX=1

HORCMINST=2

HORCMINST_AUX=3

In a cluster configuration, all servers making up the cluster must share the

HORCMINST

and

HORCMINST_AUX

instance numbers in

DEFAULT.dat

.

You can create two identical

DEFAULT.dat

files, and then place one

DEFAULT.dat

file on one

server and the other

DEFAULT.dat

file on the other server.

Table 24 Parameters in the RAID Manager-linkage definition file (DEFAULT.dat) (to specify an
instance number)

Default

Description

Parameter

Backup server

File server or database
server

None

Specify the instance number
of the instance that man-
ages the secondary volume.

Specify the instance number
of the instance that man-
ages the primary volume.

HORCMINST

#1, #2

None

Specify the instance number
of the instance that man-
ages the primary volume.

Specify the instance number
of the instance that man-
ages the secondary volume.

HORCMINST_AUX

#3

#1: The

HORCMINST

parameter is a required parameter.

Preparation for using Application Agent

116

Advertising