HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 449

Advertising
background image

8.

Transfer the temporary file to the database server.

Using

ftp

on database server B, transfer the temporary file from backup server B to database

server B:

BKServer B > ftp name-of-database-server-A

ftp> Username: (Enter the login name)

ftp> password: (Enter the password)

ftp> get 0000000013.drm

ftp> quit

BKServer B >

9.

Import the temporary file transferred from the backup server into the backup catalog on the
database server.

Execute the

drmdbimport

command on database server B to import the temporary file into the

backup catalog:

DBServer B > drmdbimport -f C:\0000000013.drm

KAVX0001-I The drmdbimport command will now start.

KAVX0418-I Backup information from the specified file was imported into the backup catalog.

Imported backup ID = 0000000012

KAVX0002-I The drmdbimport command will now end.

DBServer B >

10.

Confirm that the file was imported correctly.

Execute the

drmexgcat

command on database server B to check whether the backup catalog

information for the date that the backup was performed from the primary volume to the secondary
volume was performed has been imported on database server B:

DBServer B > drmexgcat

STRAGEGROUP: STR1

BACKUP-ID:0000000012 BACKUP-MODE: VSS STRAGEGROUP: STR1 ORIGINAL-ID:0000000011

START-TIME:2007/11/01 10:00:00 END-TIME: 2007/11/01 10:05:00 HOSTNAME:EXG_SRV1

T OBJECT INFORMATIONSTORE FILE FS DG DEVICE

COPY-GROUP

M MAILBOXSTORE MAILBOX1(STR1) D:\STR1\priv1.edb D: - Harddisk1

EXG003,B001

- - - - - - -

EXG003,B001

P PUBLICSTORE PUBLIC1(STR1) D:\STR1\pub1.edb D: - Harddisk1

EXG003,B001

- - - - - - -

EXG003,B001

T TRANSACT - E:\STR1\E00*.log E: - Harddisk2

EXG004,B001

- - - - - - -

EXG004,B001

C CHECKPOINT - E:\STR1\E00.chk E: - Harddisk2

EXG004,B001

- - - - - - -

EXG004,B001

DBServer B >

Application Agent CLI User Guide

449