8.

Check the backup catalog information that was imported into the backup server.

PROMPT> drmexgcat

STRAGEGROUP: STR1

BACKUP-ID:0000000001 BACKUP-MODE: VSS STRAGEGROUP: STR1 ORIGINAL-ID:0000000001

START-TIME:2007/11/01 10:00:00 END-TIME: 2007/11/01 10:05:00 HOSTNAME:EXG_SRV1

T OBJECT INFORMATIONSTORE FILE FS DG DEVICE

COPY-GROUP

M MAILBOXSTORE MAILBOX1(STR1) D:\STR1\priv1.edb D: - Harddisk1

EXG001,B001

- - - - - - -

EXG001,B001

P PUBLICSTORE PUBLIC1(STR1) D:\STR1\pub1.edb D: - Harddisk1

EXG001,B001

- - - - - - -

EXG001,B001

T TRANSACT - E:\STR1\E00*.log E: - Harddisk2

EXG002,B001

- - - - - - -

EXG002,B001

C CHECKPOINT - E:\STR1\E00.chk E: - Harddisk2

EXG002,B001

- - - - - - -

EXG002,B001

PROMPT>

9.

Mount the secondary volume where the backup data is stored.

Specify the backup ID that was assigned when the backup was imported (

0000000001

) to mount

the secondary volume.

PROMPT> drmmount 0000000001 -mount_pt W:

KAVX0001-I The drmmount command will now start.

KAVX0400-I Mounting will now start.

Mount point = W:

KAVX0401-I Mounting has finished.

Mount point = W:

KAVX0400-I Mounting will now start.

Mount point = X:

KAVX0401-I Mounting has finished.

Mount point = X:

KAVX0002-I The drmmount command will now end.

PROMPT>