HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 459

Advertising
background image

7.

Confirm that the file was imported correctly.

Execute the

drmexgcat

command on backup server B to check whether the backup information

for the date on which backup from the primary volume to the secondary volume was performed
was imported to backup server B.

BKServer B > drmexgcat

STRAGEGROUP: STR1

BACKUP-ID:0000000001 BACKUP-MODE: VSS STRAGEGROUP: STR1 ORIGINAL-ID:0000000001

START-TIME:2007/11/01 10:00:00 END-TIME: 2007/11/01 10:05:00 HOSTNAME:EXG_SRV1

T OBJECT INFORMATIONSTORE FILE FS DG DEVICE

COPY-GROUP

M MAILBOXSTORE MAILBOX1(STR1) D:\STR1\priv1.edb D: - Harddisk1

EXG003,B001

- - - - - - -

EXG003,B001

P PUBLICSTORE PUBLIC1(STR1) D:\STR1\pub1.edb D: - Harddisk1

EXG003,B001

- - - - - - -

EXG003,B001

T TRANSACT - E:\STR1\E00*.log E: - Harddisk2

EXG004,B001

- - - - - - -

EXG004,B001

C CHECKPOINT - E:\STR1\E00.chk E: - Harddisk2

EXG004,B001

- - - - - - -

EXG004,B001

BKServer B >

8.

Mount the secondary volume on which the backup data is stored.

Execute the

drmmount

command on backup server B to mount the secondary volume.

BKServer B > drmmount 0000000001 -mount_pt W:

KAVX0001-I The drmmount command will now start.

KAVX0400-I Mounting will now start.

Mount point = W:

KAVX0401-I Mounting has finished.

Mount point = W:

KAVX0400-I Mounting will now start.

Mount point = X:

KAVX0401-I Mounting has finished.

Mount point = X:

KAVX0002-I The drmmount command will now end.

BKServer B >