HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 479

Advertising
background image

2.

Clear the system cache right before performing a backup.

To clear the system cache, temporarily mount the secondary volume on the backup server.

PROMPT> drmmount -copy_group EXG001,B001 -mount_pt W:

KAVX0001-I The drmmount command will now start.

KAVX0400-I Mounting will now start.

Mount point = W:

KAVX0401-I Mounting has finished.

Mount point = W:

KAVX0002-I The drmmount will now end.

PROMPT> drmumount -copy_group EXG001,B001

KAVX0001-I The drmumount command will now start.

KAVX0406-I Unmounting will now start.

Mount point = W:

KAVX0407-I Unmounting has finished.

Mount point = W:

KAVX0002-I The drmumount will now end.

PROMPT> drmmount -copy_group EXG002,B001 -mount_pt X:

KAVX0001-I The drmmount command will now start.

KAVX0400-I Mounting will now start.

Mount point = X:

KAVX0401-I Mounting has finished.

Mount point = X:

KAVX0002-I The drmmount will now end.

PROMPT> drmumount -copy_group EXG002,B001

KAVX0001-I The drmumount command will now start.

KAVX0406-I Unmounting will now start.

Mount point = X:

KAVX0407-I Unmounting has finished.

Mount point = X:

KAVX0002-I The drmumount will now end.

PROMPT>

3.

On the source server, perform a VSS backup from the primary volume to the secondary volume.

A new backup ID is registered into the backup catalog.

An unused backup ID (

0000000001

) is assigned.

PROMPT> drmexgbackup -mode vss

KAVX0001-I The drmexgbackup command will now start.

KAVX0256-I A connection to the Protection Manager service will now be established.

Host name = Backupserver2

KAVX1600-I Backup processing will now start.

KAVX5108-I Resynchronizing a copy group.

Copy group name = EXG001,B001

KAVX5108-I Resynchronizing a copy group.

Copy group name = EXG002,B001

KAVX1610-I Verification of the database on the backup server will now be performed.

Storage group name = STR1

File size = file-size[MB]

KAVX1611-I Verification has finished successfully.

KAVX0040-I The backup ID has been assigned as follows:

Backup ID = 0000000001

KAVX1601-I Backup processing has finished.

KAVX0002-I The drmexgbackup command will now end.

PROMPT>