HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 506

Advertising
background image

11.

On database server 2, check the execution result of the import operation.

PROMPT> drmexgcat

STORAGEGROUP: /EXCHANGE

BACKUP-ID: 0000000001 BACKUP-MODE: VSS STORAGEGROUP: /EXCHANGE ORIGINAL-ID: 0000000001

START-TIME: 2010/01/01 11:00:00 END-TIME: 2010/01/01 11:30:00 HOSTNAME: EXG_SRV2

T OBJECT INFORMATIONSTORE FILE FS DG DEVICE COPY-GROUP

M MAILBOXSTORE Mail1 D:\Mail1\mail.edb D: - Harddisk2

EXG002,B001

- - - - - - -

EXG002,B001

T TRANSACT Mail1 E:\Mail1\E01*.log E: - Harddisk3

EXG002,B002

- - - - - - -

EXG002,B002

C CHECKPOINT Mail1 E:\Mail1\Mail2\E01.chk E: - Harddisk3

EXG002,B002

- - - - - - -

EXG002,B002

PROMPT>

12.

On backup server 2, perform a point-in-time restore operation for the backup data on the
secondary volume to the primary volume.

PROMPT> drmexgrestore 0000000002 -resync

KAVX0001-I The drmexgrestore command will now start.

KAVX0256-I A connection to the Protection Manager service will now be established.

Host name = Backupserver2

KAVX1753-I The replication function of Exchange Server has stopped. If the replication function

does not resume automatically, manually resume the replication function.

Exchange Server name = Databaseserver1

Information store name = Mail01

KAVX1808-I The information store will now be dismounted.

Information store name = Mail01

KAVX1700-I Restore processing will now start.

KAVX5111-I Performing unmounting.

Mount point name = D:

KAVX5111-I Performing unmounting.

Mount point name = E:

KAVX5108-I Resynchronizing a copy group.

Copy group name = EXG002,B001

KAVX5108-I Resynchronizing a copy group.

Copy group name = EXG002,B002

KAVX5109-I Dividing a copy group in pair.

Copy group name = EXG002,B002

KAVX5109-I Dividing a copy group in pair.

Copy group name = EXG002,B001

KAVX5111-I Performing unmounting.

Mount point name = E:

KAVX5110-I Performing mounting.

Mount point name = D:

KAVX1701-I Restore processing has finished.

KAVX1809-I The information store will now be mounted.

Information store name = Mail01

KAVX0002-I The drmexgrestore command will now end.

PROMPT>

Backing up and restoring storage groups using a tape backup
management software that is unable to link with Application
Agent

If a tape backup management software that is unable to link with Application Agent is used, follow
the steps below to back up storage groups to tape and restore them from tape. For more details on
steps 1 to 6 in the backup procedure, see “

Backing up storage groups to tape

” on page 414. For more

details on the restoration procedure, see “

Restoring storage groups from tape

” on page 419.

Operation for Exchange databases

506

Advertising