HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 442

Advertising
background image

5.

Unmount the secondary volumes on which the backup data is stored.

Execute the

drmumount

command on backup server A to unmount the secondary volume:

BKServer A > drmumount 0000000001

KAVX0001-I The drmumount command will now start.

KAVX0406-I Unmounting will now start.

Mount point = W:

KAVX0407-I Unmounting has finished.

Mount point = W:

KAVX0406-I Unmounting will now start.

Mount point = X:

KAVX0407-I Unmounting has finished.

Mount point = X:

KAVX0232-I Hid EXG001,B001.

KAVX0232-I Hid EXG002,B001.

KAVX0234-I Rerecognizes the physical volume.

KAVX0235-I Rerecognized the physical volume.

KAVX0002-I The drmumount command will now end.

BKServer A >

Execute the

drmumount

command on backup server B to unmount the secondary volume:

BKServer B > drmumount 0000000011

KAVX0001-I The drmumount command will now start.

KAVX0406-I Unmounting will now start.

Mount point = W:

KAVX0407-I Unmounting has finished.

Mount point = W:

KAVX0406-I Unmounting will now start.

Mount point = X:

KAVX0407-I Unmounting has finished.

Mount point = X:

KAVX0232-I Hid EXG003,B001.

KAVX0232-I Hid EXG004,B001.

KAVX0234-I Rerecognizes the physical volume.

KAVX0235-I Rerecognized the physical volume.

KAVX0002-I The drmumount command will now end.

BKServer B >

Restoring data using the backup data at the local site

This subsection explains the restore operation with an example of using the backup data at the local
site. The following procedure is performed entirely at the local site.

1.

Check the backup ID of the backup data.

To check the backup ID, execute the

drmtapecat

command on backup server A:

BKServer A > drmtapecat

BACKUP-ID BACKUP-OBJECT SNAPSHOT TIME EXPIRATION TIME BACKUP-MEDIA

0000000002 MSEXCHANGE 2007/11/01 11:00:00 2007/11/01 11:30:00 MEDIA1

BKServer A >

Operation for Exchange databases

442

Advertising