HP Serveur lame HP ProLiant BL465c Gen8 User Manual

Page 149

Advertising
background image

After installing Exchange Management Console, on the backup server, copy the following
files from Exchange-Server- install-destination

\bin

to Application-Agent-installation-directory

\

DRM\bin\util

:

-ESE.dll

-ESEUTIL.exe

-EXCHMEM.dll

-EXOSAL.dll

Using VSS with P9000 RMXP Shadow Copy Provider version 01-02-03/03 or
later

This subsection describes the system settings on each server when the version of P9000 RMXP Shadow
Copy Provider is 01-02-03/03 or later.

Note that if you want to perform the following operations, you can also perform setup using the method
described in “

Using VSS with P9000 RMXP Shadow Copy Provider version 01-02-03/02 or

earlier

” on page 150.

A backup to a single generation

A backup within a storage system (local backup)

Set the system environment variables for the file server or database server, as shown in the table
below.

Table 43 System environment variables required to use VSS (file server or database server)

Description

Environment vari-
able

Specify the following value:

Application-Agent-installation-destination

\DRM\conf\vssprv.conf

#

VSXPRMENVF

#

This file is for internal use of Application Agent. You do not need to specify this file.

After setting the above system environment variables, restart the OS.

Set system environment variables for the backup server, as shown in the table below.

Table 44 System environment variables required to use VSS (backupserver)

Description

System Environment Variable

Specifies the instance number of the RAID Manager
that manages the secondary volume used in VSS
backup. The specified value must be specified in the

HORCMINST

parameter of the RAID Manager-linkage

definition file (

DEFAULT.dat

).

VSXPHORCMINST_REMOTE

Application Agent CLI User Guide