Grass Valley Maestro Master Control v.1.7 User Manual

Page 165

Advertising
background image

Maestro Channel Branding User Guide

161

5th Step: Input/Output Sets

Trigger Type

Trigger Type can be “Level” or “Pulse.” If Pulse is selected, the input pulse
duration must be one field or more.

Trigger Duration

This column is not used in this application.

Trigger Sense

Select “High” if the external device is normally low and will send between
3 and 10 V to assert “Transition.” Select “Low” if the external device is nor-
mally high and will present zero V to assert “Transition.”

When finished configuring the table, select “

Apply

” or “

OK

.” The Name of

the GPIO Definition set will now appear in the set panel. The set is assigned
to the appropriate Maestro channel (Processor) using the Channel Setup
table.

Maestro Control of External Device (Action: Transition in Progress)

In this application, Maestro can send a Transition in Progress signal to an
external device. See

Figure 124

.

Note

Prior to v1.5.2, the GPO was asserted when a source began to transition. In
v1.5.2 and later the GPO is asserted as soon as the transition is triggered
whether the source begins to transition immediately or is delayed.

Figure 124. GPIO Definition table for “Transition” Trigger to Maestro

Device Type

For this application, select “MaestroGPO.”

Identifier

The numbers in this column refer to the 16 ports on the GPIO connector.
Any port from 1 to 16 can be selected in any order.

Advertising