Grass Valley Xplay Vertigo Suite v.5.0 User Manual

Page 96

Advertising
background image

Xplay User Manual

5-5

Controlling Xplay devices using automation protocols

Configuring Xplay to use the Evertz protocol over Serial

Xplay can be configured to support the Evertz protocol as a means of controlling the playout
of graphics content to Vertigo output devices. Thus far, Grass Valley has used Encoda
Automation System running the Evertz protocol (Evertz 9525 DSK-LG) controlling Xplay.

N

OTE

The Evertz protocol is somewhat limited in that there is no real control over layering of
templates on the device. Therefore, in the current implementation there is no guarantee that
a particular template will be loaded onto a particular keyer. If strict layering control is desired
then another protocol, such as Xprotocol, should be considered (see

page 5-13

).

To configure Xplay to use the Evertz protocol over Serial to control a device:
1.

Open Xplay’s D

EVICE

M

ANAGER

and verify that the devices and device keyers that the

Evertz protocol will control are properly configured and assigned (see

“Adding and

connecting Xplay to playout devices” on page 2-8

).

2.

Verify that Xplay’s A

UTOMATION

settings and the renderer’s automation settings are

appropriate for automation control (see

“Specifying Automation settings in Xplay” on

page 5-3

).

3.

Open Xplay’s A

UTOMATION

C

ONFIGURATION

window and create an instance of the

Evertz protocol for the device that is to be controlled by automation.
a.

Select T

OOLS

>C

ONFIGURE

A

UTOMATION

.

The X

PLAY

A

UTOMATION

C

ONFIGURATION

window appears (figure

5-4

).

Figure 5-4. The Xplay Automation Configuration window

b.

In the D

EVICE

TO

PROTOCOL

MAPPINGS

section, click the A

DD

P

ROTOCOL

button next

to the device that you want to map the Evertz protocol to.