Honeywell VRX180 User Manual

Page 185

Advertising
background image

Programming Function Blocks and Features

Video Recorder – User Manual

171

Table 4-74 Unit Data Prompts (continued)

Prompt

Range/Selections

Definition

SELECT FILENAME

FILE

CYCLE

DRYER

PROD RECORD

TANK

UNIT LOOP REACTR

CONFIG KILN

VESSEL

CALIB WCHEM

PRESS

FURNCE DEMIN

CONTRL

BATCH FERMTR

LEHR

LINE STRLZR

OVEN

ZONE

Select a file name to identify the type of Unit data to be
stored.

START HOUR

0-23

START MINUTE

0-59

START MONTH

JAN-DEC

START DAY

1-31

START YEAR

1994-2038

INTERVAL DAYS

0-31

INTERVAL HOURS

0-24

INTERVAL MINS

0-59

If no external enable is specified, select a starting date
and time and an interval for periodic storage. Set
Interval Days to 31 if you want the timed schedule to
repeat on the same day each month.

This timer schedule will run in any Data Storage mode. In
CONTINUOUS mode, it will start as scheduled and
collect samples until stopped by manual command (the
ENABLE STORAGE in the Online Data Storage menu).

In BATCH mode, the timer schedule will be started and
stopped by an Online menu selection (BATCH STATE)
by the operator, or by an optional discrete input
designated as the BATCH CONTROL.