MTASR1-100 Owner’s Manual

186

9.3.2 Installing the WSN Hardware Redirector Software

1.

Power on your client PC and log in to your LAN

2.

Insert the workstation diskette into your floppy disk drive. Change to your floppy disk drive, e.g., A:\, and
type INSTALL.

3.

The Installation Options Menu appears.

The checkmark in front of the options means that, by default, both options are selected for installation. If
you want to install both MCSI and WSN, press Esc and go to step 4. If you only want to install WSN, at
this time, then you must highlight Software Redirector for DOS (MCSI) and then press Enter to deselect it.
Press Esc when you are ready to continue with the installation.

4.

The Enter Pathname for WSN files window appears. Press Enter to accept the default (C:\WSN), or type
in a different pathname and press Enter, then press Esc.

5.

WSN is installed in the designated directory. When the installation is complete, the message:
"AsyncGateway WSN Installation Complete" appears. Press any key to continue. The message:
"Installation of client is completed" appears. Press any key to continue. You return to the DOS prompt.

9.3.3 Operation of the WSN Pop Up TSR

1.

Power on your client PC and login to your LAN.

2.

Your LAN’s communication link between the client PC and the MultiRouter was established by logging
onto the LAN.

3.

If you are operating from a hard disk go on to Step 5. If you are operating from a floppy disk, insert the
Dial Out Client diskette into a disk drive and change the DOS prompt to indicate that drive.

4.

Type CD WSN and press Enter. This will change the directory to the WSN directory.

OR

If you have copied the WSN files to the client PC's hard disk, change to the subdirectory containing the
WSN files.

5.

If the RD301PC was installed in your client PC with the factory default settings unchanged, you can type
WSN and press Enter. This executes the WSN redirector software, then go to Step 7. If the settings were
changed go to Step 6.

6.

If changes were made to your RD301PC's factory default settings (listed below), a parameter string must
be included after typing WSN and before pressing Enter.

When the parameter string is added to the WSN command, the line should be in the following form:

WSN -itx -byyy -cz

WSN default is: -it7 -b100 -c3

The x, yyy and z values are taken from the settings of the DIP switches and/or jumpers of the RD301PC
at each client PC.

x is equal to the setting of DIP Switches 1-6 on Switch Bank #3.

yyy is equal to the setting of DIP Switch Bank #2