Full Status Enquiry Interval (N391)

Link Integrity Verification is used to determine the status of the channel and hence to update the staus of
PVCs. Value specified is in seconds.

Range: 1-255

Recommended Value: 6

Error Threshold (N392)

The Error Threshold is the number of events that should occur without any errors.

Range: 1-10

Recommended Value: 3

Monitored Events Count (N393)

This value specifies the number of events that could occur with a maximum Error Threshold so that the link
could be restored in case of failure.

Range: 1-10

Recommended Value: 4

Note: The Error Threshold should be less than or equal to the Monitored Events Count. If Monitored Events
Count is set to a value much less that the Full Status Enquiry Interval, then the link could go in and out of error
condition without the user equipment or network being notified.

Link Integrity Verification Timer (T391)

This value specifies the period for the timer. Its value is specified in seconds.

Range: 5-30

Recommended Value: 5

Polling Verification Timer (T392)

The Polling Verification Timer specifies the maximum amount of time (in seconds) the network should wait for
a response from the remote user equipment.

Range: 5-30

Recommended Value: 10

Note: The Polling Verification Timer should not be greater than the Link Integrity Verification Timer.