Error control operation +eb, Numeric parameter control +efcs – Multi-Tech Systems CDMA Wireless Modem User Manual

Page 133

Advertising
background image

Chapter 17 – Extended AT Commands in IS707.3

Multi-Tech Systems, Inc. CDMA Wireless AT Commands - PN S000294C

133

Error Control Operation +EB

Description: This command is used for break handling in error control operations. The extended-format

compound parameter is used to control the manner of V.42 operation on the PSTN line (if
present in IWF). The command is not relevant for packet service. For more details on the
command, refer to IS707.3.


Values:

<Break_selection>

0: Ignore break (do not signal to remote DCE)
1: Non-expedited, non-destructive
2: Expedited, non-destructive
3: Expedited and destructive

<timed>

0: Any transmitted V.42 L-SIGNAL shall not indicate break signal length
1: Any transmitted V.42 L-SIGNAL shall indicate break signal length

<default_length>

0: Do not deliver break to DTE
1-254: Default break length of .01 to 2.54 seconds


Syntax:

Command syntax: AT+EB=[<Break_selection>[,<timed>[,<default_length>]]]

Command

Possible Responses

AT+EB?
Note: Display the current setting.

+EB: 1,0,30
OK
Note: This is the default setting

AT+EB=2
Note: Set value to 2.

OK
Note: Command is valid

Numeric Parameter Control +EFCS

Description: The extended-format numeric parameter is used to control the use of 32-bit frame check

sequence option in V.42 on the PSTN link (if present in IWF). The command is not relevant
for packet service.


Values:

<Val>

0: Use 16-bit FCS
1: Use 32-bit FCS if available in remote DCE; otherwise use 16-bit FCS
2: Use 32-bit FCS if available in remote DCE; otherwise disconnect


Syntax:

Command syntax: AT+EFCS=[<Val>]

Command

Possible Responses

AT+EFCS?
Note: Display the current setting.

+EFCS: 0
OK
Note: Command is valid

AT+EFCS=2
Note: Set value to 2.

OK
Note: Command is valid