Excess SPC Failures +WLCK

Description: This response indicates that 15 failed attempts have been made to enter the service

programming code. If the modem is not in emergency mode, any active call will be
terminated and the modem will go into offline mode.


Note: A successfully entered service programming code grants access to modem
configuration data.


Syntax:

Response Syntax: +WLCK: “Excess SPC failures!”

Command

Possible Responses

AT+WSPC=0,123456
Note: 15

th

attempt to enter the SPC.

+WLCK: “Excess SPC failures!”
Note: Modem now in offline mode.

Position Determination Lock Level +WPLCK

Description: This command specifies and returns the position determination lock setting. If the lock is set

to ‘lock all’, then only E911-related position determination events are allowed and all other
position determination requests are denied.


Values:

<level>

0: No lock (allow all)
1: Lock mobile initiated location services
2: Lock mobile terminated location services
3: Lock all


Syntax:

Command syntax: AT+WPLCK=<level>

Command

Possible Responses

AT+WPLCK=?
Note: Display valid parameter range

+WPLCK: (0-3)
OK

AT+WPLCK?
Note: Request current setting type

+WPLCK: 0
OK

AT+WPLCK=3
Note: Select lock all

OK