Iwf device identification +cgoi, Packet data inactivity timer +cta – Multi-Tech Systems CDMA Wireless Modem User Manual

Page 147

Advertising
background image

Chapter 17 – Extended AT Commands in IS707.3

Multi-Tech Systems, Inc. CDMA Wireless AT Commands - PN S000294C

147

IWF Device Identification +CGOI

Description: This command causes the IWF to transmit one or more lines of information text, determined

by the manufacturer, which is intended to permit the user of the IWF to identify the device,
based on the ISO system for registering unique object identifiers. Typically, the text will
consist of a single line containing numeric strings delimited by period characters

.


Syntax:

Command syntax: AT+CGOI

Command

Possible Responses

AT+CGOI
Note: Display the current settings.

OK
Note: Command is valid.

AT+CGOI=0
Note: Set the value to 0.

ERROR
Note: Command is not valid.

U

m

Packet Data Inactivity Timer +CTA

Description: This command is used to Set, Read, and Test the Um packet data inactivity timer.

Values:

<val>

0: Traffic Channel not released during inactivity periods.
20-255: Release the Traffic Channel after <value> 1-second intervals have elapsed
since last sending or receiving RLP data frames on the Um interface.


Syntax:

Command syntax: AT+CTA=<val>

Command

Possible Responses

AT+CTA ?
Note: Display the current setting.

+CTA: 0
OK
Note: Command is valid

AT+CTA=?
Note: Display valid parameter range.

+CTA: (0-255)
OK
Note: Command is valid

AT+CTA=1 Note: Set to one second.

OK
Note: Command is valid