Chapter 17 – Extended AT Commands in IS707.3

Multi-Tech Systems, Inc. CDMA Wireless AT Commands - PN S000294C

139

V.18 Selection +MV18S

Description: The extended-format numeric parameter is used to control the manner of operation of the

V.18 capabilities (if present) in the DCE.


Values:

<mode>

0: Disables V.18 connection
1: V.18 operation, auto detect mode
2: V.18 operation, connection in 5-bit mode
3: V.18 operation, connect in DTMF mode
4: V.18 operation, connect in EDT mode
5: V.18 operation, connect in V.21 mode
6: V.18 operation, connect in V.23 mode
7: V.18 operation, connect in Bell 103-type mode

<dflt_ans_mode>

0: disables V.18 answer operation
1: no default specified (auto detect)
2: V.18 operation, connect in 5-bit mode
3: V.18 operation, connect in DTMF mode
4: V.18 operation, connect in EDT mode

<fbk_time_enable>

0: disable
1: enable


Syntax:

Command syntax: AT+MV18S=[<mode>[,<dflt_ans>[,<fbk_time_enable>]]]

Command

Possible Responses

AT+MV18S?
Note: Display the current setting.

+MV18S: 0, 0, 0
OK
Note: Command is valid

AT+MV18S=1,1,1
Note: Set mode value to 1.

OK
Note: Command is valid

AT+MV18S?
Note: Display the current setting.

+MV18S: 1, 1, 1
OK
Note: Command is valid

Cellular Extension +CXT

Description

:

The numeric parameter is used for cellular extension.


Values:

<Val>

0: Do not pass unrecognized commands to the IWF
1: When detecting an unrecognized AT command, open transport layer connection and
pass unrecognized command to the IWF.


Syntax:

Command syntax: AT+CXT=<Val>

Command

Possible Responses

AT+CXT?
Note: Display the current setting.

+CXT: 0
OK
Note: Command is valid

AT+CXT=?
Note: Display the range of setting.

+CXT: (0-1)
OK
Note: Command is valid

AT+CXT=1
Note: Enable extension.

OK
Note: Command is valid