Hapter, Ommands – Multi-Tech Systems CDMA Wireless Modem User Manual

Page 72

Advertising
background image

Chapter 10 – Data Commands

Multi-Tech Systems, Inc. CDMA Wireless AT Commands - PN S000294C

72

C

HAPTER

10

-

D

ATA

C

OMMANDS

Using AT Commands During a Data Connection

To use AT Commands during a data connection (e.g. while the product is in online mode), it is necessary
either to switch to offline mode, or to use the +WMUX command to enable Commands / Data multiplexing.
Note: currently the +WMUX command is not supported yet.
Switch From Online to Offline Mode
To switch from online mode to offline mode, the “+++” sequence must be sent. Following this, the product
gets back to offline mode with an “OK” response, and an AT command can be sent.

Note: the “+++” sequence only works with the +ICF command using the following settings:

• 8 data bits, with no parity

• 7 data bits, with even parity

Switch From Offline to Online Mode
See the ATO command description.

Select Mode +FCLASS

Description: This command puts the product into a particular operating mode for fax.

Values:

<n>

0: Data
1: Fax class 1
2.0: Fax class 2.0

Syntax:

Command syntax: AT+FCLASS= <n>

Command

Possible Responses

AT+FCLASS=?
Note: Test command

+FCLASS: 0, 2.0
OK
Note: If fax class 1 not supported

AT+FCLASS=0
Note: Data mode requested

OK
Note: Command valid

AT+FCLASS=2.0
Note: Fax class 2 mode requested

OK
Note: Command valid

AT+FCLASS?
Note: Current value

+FCLASS: 2.0
OK
Note: Command valid

Advertising