Chapter 2 Wiring

2.3.5 W

ring for extension I/O units

131

(3) Connection of PIO

The connection of I/O to the controller is to be carried out using the dedicated I/O cable. The

cable length is shown in the model code of the controller. Please check the controller model

code. There are 2m for standard, 3m and 5m as an option. 10m is also applicable at maximum

[Refer to “1.1.5 How to read the model”]

Also, the end of the cable harness to be connected to the host controller (PLC, etc.) is just cut

and no treatment is conducted so the wiring layout can be performed freely.

� 32 Input Points / 16 Output Points, 16 Input Points / 32 Output Points

Model : CB-X-PIO ���

(��� indicates the cable length L. Example. 020 = 2m)

No.

Cable

color

Wiring

No.

Cable

color

Wiring

1

Brown-1

26

Blue-3

2

Red-1

27

Purple-3

3

Orange-1

28

Gray-3

4

Yellow-1

29

White-3

5

Green-1

30

Black-3

6

Blue-1

31

Brown-4

7

Purple-1

32

Red-4

8

Gray-1

33

Orange-4

9

White-1

34

Yellow-4

10

Black-1

35

Green-4

11

Brown-2

36

Blue-4

12

Red-2

37

Purple-4

13 Orange-2

38

Gray-4

14

Yellow-2

39

White-4

15

Green-2

40

Black-4

16

Blue-2

41

Brown-5

17

Purple-2

42

Red-5

18

Gray-2

43

Orange-5

19

White-2

44

Yellow-5

20

Black-2

45

Green-5

21

Brown-3

46

Blue-5

22

Red-3

47

Purple-5

23 Orange-3

48

Gray-5

24

Yellow-3

49

White-5

25

Green-3

Flat cable

(Press welding)

AWG28

50

Black-5

Flat cable

(Press welding)

AWG28

[Refer to 2.2.10 Extension I/O unit (Option) for the signal assignment for each cable]

Cutting state

49

1

2

50

Socket (with strain relief) : XG4M-5030-T (Manufacturer: Omron))

Flat cable (50 conductors) : KFX-50 (S) (Manufacturer: Kaneko Cord)

Advertising