3 axis-specific parameters, 1 for xsel-r/s – IAI America XSEL-S User Manual

Page 352

Advertising
background image

Chapter 6 Parameter

6.3

Axis-Specific Parameters

.6.3.1 For XSEL-R/S

344

6.3 Axis-Specific Parameters

6.3.1 For XSEL-R/S

No.

Parameter name

Default value

(reference)

Input range

Unit

Remarks

1

Axis operation type

0

0 to 1

0: Linear movement axis

1: Rotation movement axis

(angle control)

2

ACMX+Acceleration 1

30

1 to 999

0.01G

Acceleration speed when ACMX

Command is executed.

• Acceleration of movement in positive

direction of the cooperate system

• Deceleration of movement in negative

direction of the cooperate system

Setting is established based on

transported weight, installation

condition, etc.

3

ACMX-Acceleration 1

30

1 to 999

0.01G

Acceleration speed when ACMX

Command is executed.

• Acceleration of movement in negative

direction of the cooperate system

• Deceleration of movement in positive

direction of the cooperate system

Setting is established based on

transported weight, installation

condition, etc.

4

ACMX+Acceleration 2

30

1 to 999

0.01G

Same as Each Axis Parameter No. 2

5

ACMX-Acceleration 2

30

1 to 999

0.01G

Same as Each Axis Parameter No. 3

6

Coordinate/

physical-operation direction

selection

1

0 to 1

0: Motor CCW�Positive direction of

coordinate

1: Motor CCW�Negative direction of

coordinate

Change Prohibited

7

Soft limit +

50000

-99999999 to

99999999

0.001mm

0.001deg

Fixed at 359.999deg inside when index

mode

Invalid when infinite stroke mode

8

Soft limit –

0

-99999999 to

99999999

0.001mm

0.001deg

Fixed at 0deg inside when index mode

Invalid when infinite stroke mode

9

Soft-limit actual position

margin

2000

0 to 9999

0.001mm

0.001deg

Positioning boundary critical zone actual

position margin when infinite stroke

mode

10 How to return home

0

0 to 5

0: Z-phase search after end search

1: Current position at 0 home position

(available only when INC encoder,

pay attention to interference)

2: Current Position = Home preset value

(available only when INC encoder,

pay attention to interference)

3: Home preset automatic update datum

coordinates move after end search

* Available only for ball screw spline

linear movement axis

* Related Information:

Each Axis Parameter No.10, 12,

141

4: Home position sensor detection

range center point calculation method

(Main application of Ver. 0.05 or later)

* When Each Parameter No. 166 is set

to 1 (Drive Invalid), current position =

home position preset value set no

matter of this setting.

11 Select Home-Return End

Search Direction

0

0 to 1

0: Coordinate negative end

1: Coordinate positive end

12 Home Preset Value

0

-99999999 to

99999999

0.001mm

0.001deg

Advertising