IAI America XSEL-S User Manual

Page 324

Advertising
background image

Chapter 6 Parameter

6.1 I/O Parameter (All types)

316

I/O Parameter (All types)

No.

Parameter name

Default

value

(reference)

Input

range

Unit

Remarks

534 Extension Motion Control

Board 0

th

Axis Control Attribute 00000000H

0H to

FFFFFFFFH

Bits 0 to 3: Control input and output port

assignment type

0: Assignment invalid (control input and

output port not to be used)

1: APCON type assignment

Input port No.n: Servo-on signal

Input port No.n+1: Positioning

completion signal

Input port No.n+2: Home return

complete signal

Input port No.n+3: Alarm signal

Output port No.m: Servo ON

Command signal

Output port No.m+1: Home return

command signal

Output port No.m+2: Alarm reset

command signal

2: SCON type assignment

Input port No.n: Servo-on signal

Input port No.n+1: Positioning

completion signal

Input port No.n+2: Home return

complete signal

Input port No.n+3: Alarm signal

Input port No.n+4: Operating mode

status signal

Output port No.m: Servo-on command

signal

Output port No.m+1: Home return

command signal

Output port No.m+2: Alarm reset

command signal

3: A/PCON type assignment

(Pulse cable disconnection detection

signal assignment)

Input port No.n: Servo-on signal

Input port No.n+1: Positioning

completion signal

Input port No.n+2: Home return

complete signal

Input port No.n+3: Alarm signal

Input port No.n+4: Pulse cable

disconnection detection signal

Output port No.m: Servo-on command

signal

Output port No.m+1: Home-return

command signal

Output port No.m+2: Alarm reset

command signal

* n = setting of Parameter No. 535 “Extension

Motion Control Board 0

th

Axis Control Top Input

Port Number”

* n = setting of Parameter No. 536 “Extension

Motion Control Board 0

th

Axis Control Top Output

Port Number”

Note: Dedicated for XSEL-R/S controller

535

Extension Motion Control

Board 0

th

Axis Control Top Input

Port Number

0

0 to 3999

Note: Dedicated for XSEL-R/S controller

536

Extension Motion Control

Board 0

th

Axis Control Top

Output Port Number

0

0 to 6999

Note: Dedicated for XSEL-R/S controller

537 Extension Motion Control

Board 1

st

Axis Control Attribute 00000000H

0H to

FFFFFFFFH

(*Same as I/O parameter No. 534)

Note: Dedicated for XSEL-R/S controller

Advertising