3 error list (main application) – IAI America XSEL-S User Manual

Page 418

Advertising
background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

410

7.3 Error List (MAIN application)


In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

200 Encoder parameter data version

mismatch warning

The version of encoder parameter data is not supported by

this controller. Update the encoder parameters.

201 EMG logic error

A broken pin in the controller is suspected

202 ENB logic error

A broken pin in the controller is suspected

203 Drive-source cutoff relay DET

(MELT) error

The drive-source cutoff relay may have fused.

206 Updating system mode error (IAI

protocol)

An update command was received other than in the

update mode.

207 Update file name error (IAI

protocol)

The name of the update program file selected in the

update mode is invalid.

Select the correct file and repeat the updating procedure

from the beginning.

208 Time data error

The time data is invalid. Check the data.

209 Unsupported control constant table

ID error

The control constant table ID is not supported.

Check the data.

20A Control constant table

change/query error

The message of the control constant table change/query

command contains error.

Check the message that has been sent.

20B Control constant table write data

type specification error

The specified control constant table write data type is

invalid.

Check the message that has been sent.

20C Control constant table

management information mismatch

error

The management information regarding the control

constant table is invalid.

Confirm that the control constant table is supported by the

controller.

20D Flash busy reset timeout error

Error erasing/writing the flash ROM

20E Motorola S-byte count error

The update program file is invalid.

Check the file.

20F Updating target specification error

(Received by the application)

The system application received an updating target

specification command.

To update the program, restart the controller and repeat

the updating procedure from the beginning.

211 IA Net link error�

IA Net link error was detected.

Check if the stations indicated in I/O parameters No. 605

and 606 are connected to IA Net properly, or if the station

numbers are duplicated in the IA Net network.�

212 IA Net break station detection error A station that cannot be joined in the IA Net communication

cycle was detected.

Check if there is a controller or unit with the station number

greater than what is set in I/O parameter No. 604 “IA Net

Final Station Number”�

213 IA Net mail undefined error code

receive error�

Undefined IA Net mail error code was received.

There is a concern that there is a function that is available

in other controllers and units in the IA Net network, but is

not available on this controller.

Update the application in the main CPU board.�

214 IA Net stop detection error�

IA Net stop detection error was detected.

Check if there is an IA Net related error being occurred.�

215 External terminal block overcurrent

or power supply failure�

Overcurrent on external terminal block or an error in the

power supply to external terminal block�

216 DO output current error�

There is a failure in DO output current.�

M

es

sa

ge

le

ve

l e

rro

rs

217 24V I/O power supply failure�

There is a failure in 24V I/O power supply.�

Advertising