Troubleshooting

7.3 Error List (MAIN application)

451

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

C3A User-open communication channel

number error

The channel number of the communication channel

opened to the user is invalid.

C3B Parameter number error

The parameter number is invalid.

C3C Variable number error

The variable number is invalid.

C3D String number error

The string number is invalid.

C3E String-variable data count

specification error

The specified number of string variables exceeds the area,

etc.

C40 String-variable delimiter

non-detection error

Delimiter cannot be detected in the string variable.

C41 String-variable copy size over error The copy size of string variable is too large.
C42 Character count non-detection

error during string processing

The character-string length is not defined in string

processing.

Execute a string processing command after defining the

length with a SLEN command.

C43 Character-string length error during

string processing

The character-string length used in string processing is

invalid.

Check the value of character-string length defined by a

SLEN command.

C45 Symbol definition table number

error

The symbol definition table number is invalid.

C46 Blank area shortage error with

source-symbol storage table

There is not enough area to store the source symbols.

Check the number of times source symbol can be used.

C47 Symbol search error

Definitions are not found for the symbols used in the

program steps.

C48 SIO-message continuous

conversion error

The transmitted SIO message does not match the

message format or contains invalid data.

Check the transmitted message.

C49 SEL-SIO in-use error

The SIO is being used by other interpreter task.

C4A SCIF unopen error

Serial channel 1 opened to the user is not opened in the

target task.

Open the channel using an OPEN command first.

C4B Delimiter non-definition error

An end character is not defined.

Set an end character using a SCHA command first.

C4E SIO invalid usage OPEN error

The usage of serial channel opened to the user does not

match the parameter.

Check “I/O parameter No. 90, Usage of SIO channel

opened to user.”

C4F SEL program/source symbol

checksum error

The flash ROM data has been destroyed.

C50 Symbol definition table checksum

error

The flash ROM data has been destroyed.

C51 Position data checksum error

The flash ROM data has been destroyed.

C53 Invalid flash-ROM SEL global

data/error list error

The SEL global data/error lists in the flash ROM are

invalid.

C54 Flash-ROM SEL global data/error

list duplication error

The SEL global data/error lists in the flash ROM are

duplicated.

C55 Flash-ROM erase count over error

for SEL global data/error lists

The number of time the flash ROM containing SEL global

data/error lists can be erased was exceeded.

C56 Timing limit over error (Flash ROM

erase)

Error erasing the flash ROM

C57 Flash-ROM verify error (Flash

ROM erase)

Error erasing the flash ROM

O

pe

ra

tio

n-

ca

nc

el

la

tio

n

le

ve

l e

rro

rs

C58 Flash-ROM ACK timeout error

(Flash ROM erase)

Error erasing the flash ROM

Advertising