IAI America XSEL-S User Manual

Page 466

Advertising
background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

458

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

D40 Coordinate system data control

domain sum check error

Coordinate system data is destroyed.

Initialize the coordinate system data.

D41 Coordinate system data control

domain ID error

Coordinate system data is destroyed.

Initialize the coordinate system data.

D42 Coordinate system data sum check

error

Coordinate system data is destroyed.

Initialize the coordinate system data.

D43 Fan error

The fan is stopped or degenerated.

It should be replaced, because it might heat up because of

the controller’s fan stop.

D44 Baseboard CPU error

There is an error on baseboard CPU.

D45 Hardware and software mismatch

error

System software that is not compatible with the hardware

is being updated.

Check the compatibility of the system software with the

hardware and update again.

D50 Fieldbus error (FBMIRQ timeout)

A FBMIRQ timeout was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D51 Fieldbus error (FBMIRQ reset)

A FBMIRQ reset error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D52 Fieldbus error (FBMBSY)

A FBMBSY was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D53 Fieldbus error (BSYERR)

A BSYERR was detected. The power must be

reconnected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D54 Window lock error (LERR)

A LERR was detected. The power must be reconnected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D55 Fieldbus error (Min busy)

A Min busy error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D56 Fieldbus error (MinACK timeout)

A Min ACK timeout was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D57 Fieldbus error (MoutSTB timeout) A Mout STB timeout was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

D58 Fieldbus error (INIT timeout)

An INIT timeout was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.

Cold-st

art

lev

el

errors

D59 Fieldbus error (DPRAM write/read) A DPRAM write/read error was detected.

Check the statuses of monitor LEDs on the front panel of

the board by referring to the operation manual for the field

network board.