7.3 Error List (MAIN application)
458
In the panel window, the error numbers follow E in the display.
Error
No.
Error name
Description, action, etc.
D40 Coordinate system data control
domain sum check error
Coordinate system data is destroyed.
Initialize the coordinate system data.
�
D41 Coordinate system data control
domain ID error
�
Coordinate system data is destroyed.
Initialize the coordinate system data.
�
D42 Coordinate system data sum check
error
�
Coordinate system data is destroyed.
Initialize the coordinate system data.
�
D43 Fan error
The fan is stopped or degenerated.
It should be replaced, because it might heat up because of
the controller’s fan stop.
D44 Baseboard CPU error
There is an error on baseboard CPU.
D45 Hardware and software mismatch
error
System software that is not compatible with the hardware
is being updated.
Check the compatibility of the system software with the
hardware and update again.
D50 Fieldbus error (FBMIRQ timeout)
A FBMIRQ timeout was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D51 Fieldbus error (FBMIRQ reset)
A FBMIRQ reset error was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D52 Fieldbus error (FBMBSY)
A FBMBSY was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D53 Fieldbus error (BSYERR)
A BSYERR was detected. The power must be
reconnected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D54 Window lock error (LERR)
A LERR was detected. The power must be reconnected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D55 Fieldbus error (Min busy)
A Min busy error was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D56 Fieldbus error (MinACK timeout)
A Min ACK timeout was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D57 Fieldbus error (MoutSTB timeout) A Mout STB timeout was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
D58 Fieldbus error (INIT timeout)
An INIT timeout was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.
Cold-st
art
lev
el
errors
D59 Fieldbus error (DPRAM write/read) A DPRAM write/read error was detected.
Check the statuses of monitor LEDs on the front panel of
the board by referring to the operation manual for the field
network board.