6 regenerative unit: reu-1 – IAI America XSEL-S User Manual

Page 70

Advertising
background image

Chapter 1 Specifications Check

1.4.6 Regenerative Unit: REU-1

62

1.4.6 Regenerative Unit: REU-1

Regenerative resistance unit: A unit that converts to heat the regenerative current generated

when the motor decelerates.

[Specification]�

Item

Specification

Internal Regenerative Resistor

235� 80W

Accessories

(Note1)

Controller Connection Cable (ModelCB-ST-REU010) 1m

Surrounding air temperature

0 to +40�C

Surrounding humidity

85%RH or less (non-condensing)

Surrounding environment

(Refer to the Item for the Installation Environment).

Surrounding storage

temperature

-20 to 70�C

Surrounding storage humidity

85% or less (non-condensing)

Protection Class

IP20

Environment�

Pollution Degree

Pollution Degree 2

External Dimensions

34Ч195Ч126mm

Weight�

0.9kg

Note 1 Refer to 2.3.7 for the details of the cable.

[External Dimensions]�
















φ

5

RB

RB-

16.6

126

34

5

57

1

59

1

68

1

RB+

RB-

RB+

OUT

RB IN

Advertising