7.3 Error List (MAIN application)
450
In the panel window, the error numbers follow E in the display.
Error
No.
Error name
Description, action, etc.
C16 Create stack failed
Initialization of the input-condition-status storage stack has
failed.
C17 Expansion-condition code error
Input program step error. The expansion condition code is
invalid.
C18 Expansion-condition LD
simultaneous processing over error
The number of LDs processed simultaneously exceeds the
limit value.
C19 Expansion-condition LD shortage
error 1
There is not enough LD when expansion condition A or O
is used.
C1A Expansion-condition LD shortage
error 2
There is not enough LD when expansion condition AB or
OB is used.
C1C Unused-LD detection error
An attempt was made to execute a command based on
multiple LD condition that has been saved, without using it
in expansion condition AB or OB.
C1F Input-condition CND shortage error The necessary input condition is not found when an
expansion condition is used.
C21 Input-condition use error with
input-condition prohibited
command
Input-condition prohibited commands prohibit the use of
input conditions.
C22 Invalid command position error
with input-condition prohibited
command
A command for which input condition is prohibited cannot
be included in an input condition nest.
C23 Invalid operand error
Program step error. The necessary operand data is invalid.
C24 Operand type error
Program step error. The operand data type is invalid.
C25 Actuator control declaration error
The setting of actuator control declaration command is
invalid.
C26 Timer setting-range over error
The timer setting is invalid.
C27 Timeout setting-range over error
during wait
The timeout setting is invalid.
C28 Tick count setting-range error
The Tick count setting is invalid.
C29 DIV command divisor 0 error
“0” was specified as the divisor in the DIV command.
C2A SQR command range error
The operand value in the SQR command is invalid. Input a
value larger than “0” as data in a SQR command.
C2B BCD display digit range error
The specified number of BCD display digits is invalid.
Specify a value between 1 and 8.
C2C Program number error
A number not yet registered among program Nos. 1 to 64
was specified.
C2D Step number error
The step number is invalid.
C2E Blank step shortage error
There are not enough blank steps to save step data.
Provide enough blank steps needed to save step data.
C2F Axis number error
The axis number is invalid.
C30 Axis pattern error
The axis pattern is invalid.
C32 Operating-axis addition error
during command execution
An operation axis of the position data was added during
the calculation process of the continuous position
movement or pressing movement.
C33 Base axis number error
The base axis number is invalid.
C34 Zone number error
The zone number is invalid.
C35 Position No. error
The Position No. is invalid.
C36 I/O port/flag number error
The I/O port/flag number is invalid.
C37 Flag number error
The flag number is invalid.
C38 Tag number error
The tag number is invalid.
C39 Subroutine number error
The subroutine number is invalid.