IAI America XSEL-S User Manual

Page 458

Advertising
background image

Chapter 7

Troubleshooting

7.3 Error List (MAIN application)

450

In the panel window, the error numbers follow E in the display.

Error

No.

Error name

Description, action, etc.

C16 Create stack failed

Initialization of the input-condition-status storage stack has

failed.

C17 Expansion-condition code error

Input program step error. The expansion condition code is

invalid.

C18 Expansion-condition LD

simultaneous processing over error

The number of LDs processed simultaneously exceeds the

limit value.

C19 Expansion-condition LD shortage

error 1

There is not enough LD when expansion condition A or O

is used.

C1A Expansion-condition LD shortage

error 2

There is not enough LD when expansion condition AB or

OB is used.

C1C Unused-LD detection error

An attempt was made to execute a command based on

multiple LD condition that has been saved, without using it

in expansion condition AB or OB.

C1F Input-condition CND shortage error The necessary input condition is not found when an

expansion condition is used.

C21 Input-condition use error with

input-condition prohibited

command

Input-condition prohibited commands prohibit the use of

input conditions.

C22 Invalid command position error

with input-condition prohibited

command

A command for which input condition is prohibited cannot

be included in an input condition nest.

C23 Invalid operand error

Program step error. The necessary operand data is invalid.

C24 Operand type error

Program step error. The operand data type is invalid.

C25 Actuator control declaration error

The setting of actuator control declaration command is

invalid.

C26 Timer setting-range over error

The timer setting is invalid.

C27 Timeout setting-range over error

during wait

The timeout setting is invalid.

C28 Tick count setting-range error

The Tick count setting is invalid.

C29 DIV command divisor 0 error

“0” was specified as the divisor in the DIV command.

C2A SQR command range error

The operand value in the SQR command is invalid. Input a

value larger than “0” as data in a SQR command.

C2B BCD display digit range error

The specified number of BCD display digits is invalid.

Specify a value between 1 and 8.

C2C Program number error

A number not yet registered among program Nos. 1 to 64

was specified.

C2D Step number error

The step number is invalid.

C2E Blank step shortage error

There are not enough blank steps to save step data.

Provide enough blank steps needed to save step data.

C2F Axis number error

The axis number is invalid.

C30 Axis pattern error

The axis pattern is invalid.

C32 Operating-axis addition error

during command execution

An operation axis of the position data was added during

the calculation process of the continuous position

movement or pressing movement.

C33 Base axis number error

The base axis number is invalid.

C34 Zone number error

The zone number is invalid.

C35 Position No. error

The Position No. is invalid.

C36 I/O port/flag number error

The I/O port/flag number is invalid.

C37 Flag number error

The flag number is invalid.

C38 Tag number error

The tag number is invalid.

C39 Subroutine number error

The subroutine number is invalid.

Advertising