2 parameters common to all axes, 1 for xsel-r/s – IAI America XSEL-S User Manual

Page 334

Advertising
background image

Chapter 6 Parameter

6.2 Parameters Common to

All

Axes

6.2.1 For XSEL-R/S

326

6.2

Parameters Common to All Axes

6.2.1 For XSEL-R/S

No.

Parameter name

Default

value

(reference)

Input range

Unit

Remarks

1 Valid axis pattern

111111B

00B to

11111111B

OFF Bit: Setting of driver not mounted

2 Default override

100

1 to 100

Used if not specified in program.

(Invalid for SIO operation)

3 (For expansion)

0

4 (For expansion)

0

5 (For expansion)

0

6 (For expansion)

0

7 (For expansion)

0

8 (For expansion)

0

9

Enable switch (Deadman

switch/Safety gate) effective

physical axis pattern

11111111B

00B to

11111111B

It does not get influence of ASE Command. (For

all axes (= basic), make sure to indicate 11111111.

The enable switch gets involved in the drive

source cutoff factor only when it is set to 11111111,

and in cases other than 11111111, drive source

cutoff would not be conducted, and only the

indicated axis servo will be turned off. (“enb” not

displayed on 7-segment display windows)

* When “Other Parameter No. 11 Recovery Type

at Enable Switch (Dead man’s switch and

safety gate) Open” = 1 (Reset Recovery

Required), the setting will be identified as the

indication of all axes.

* An axis with no motor drive power part built in

this controller or that with the drive source cutoff

circuit not under the control of this controller

cannot make a drive source cutoff.

* For the option (special order) type, the priority is

given to the option (special order) specifications

such as the dead man’s switch effective physical

axis, drive source cutoff, servo-off and the display

of 7-segment display windows.

10 Reserved by the system

(change is prohibited).

0

11 Default acceleration

30

1 to 200

0.01 G Used if not specified in position data, program or

SIO message, etc.

12 Default deceleration

30

1 to 200

0.01 G Used if not specified in position data, program or

SIO message, etc.

13 Default speed

30

1 to 250

mm/s Used if not specified in SIO message or position

data, when movement is to be continued, etc.

14 Valid selection when operation

position data deceleration is 0

0

0 to 5

0: “Deceleration = Acceleration” when the

deceleration in the operation position data is

“0”

1: “Deceleration = 0” when the deceleration in

the operation position data is “0”

15 Maximum JOG speed at home

return incomplete

30

1 to 250

mm/s

16 Reserved by the system

(change is prohibited).

0

Advertising
This manual is related to the following products: