9 manual operation types – IAI America XSEL-S User Manual

Page 396

Advertising
background image

Chapter 6 Parameter

6.9 Manual Operation

Types

388

6.9 Manual Operation Types

By setting to Parameter “Manual Operation Type” (Other Parameter No. 21), the parameter

can be changed so SIO program startup and PIO program startup cannot be conducted

without inputting a password.

(1) PC software

[1] Setting = 0 (Always enable edit and SIO/PIO start)

Functions

Operation type

Password

Edit

Safety speed

Jog, move,

continuous

move

SIO program

start

PIO program

start

With safety speed

Not required

Without safety

speed

Not required

[2] Setting = 1 (Select edit and start (with password))

Functions

Operation type

Password

Edit

Safety speed

Jog, move,

continuous

move

SIO program

start

PIO program

start

Edit and jog

Not required

SIO start and jog

(safety speed)

1817

SIO start and jog

1818

SIO/PIO start and

jog

1819

(2) Teaching pendant

[1] Setting = 0 (Always enable edit and SIO/PIO start)

Functions

Safety-speed enable

selection

Password

Edit

Safety speed

Jog, move,

continuous

move

SIO program

start

PIO program

start

Enable

Not required

Disable

Not required

[2] Setting = 1 (Select edit and start (with password))

Functions

Safety-speed enable

selection

Password

Edit

Safety speed

Jog, move,

continuous

move

SIO program

start

PIO program

start

Enable

Not required

(*2)

Disable

1818

(*2)

Functions

PIO start prohibition

selection

Password

Edit

Safety speed

Jog, move,

continuous

move

SIO program

start

PIO program

start

Prohibit

Not required

(*3)

Enable

1819

(*3)

(*1) PIO program start is enabled only in modes other than the edit mode.

(*2) In accordance with the “PIO start prohibition selection” setting.

(*3) In accordance with the “Safety-speed enable” setting.

*1

*1

*1

Advertising